PM5317 SPECTRA-9953 Telecom Standard Product Data Sheet
Release
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2000741, Issue 5
499
Equation 5:
Alarm =
(RSALM
(MSRSALM
(PLOPTR
(PAISPTR
(PPLU AND PPLUEN
(PPLM AND PPLMEN
(PUNEQ
(PPDI AND PPDIEN
(PRDI AND PRDIEN
(PERDI AND PERDIEN
(PTIU AND PTIUEN
(PTIM AND PTIMEN
AND RSALMEN
AND MSRSALMEN ) OR
AND PLOPTREN
AND PAISPTREN
) OR
) OR
) OR
) OR
) OR
AND PUNEQEN
) OR
) OR
) OR
) OR
)
) OR
The RPAISINS indication is defined by Equation 6. The bits from and including RLAISINSEN
to PTIMEN in the Indirect Register 2H: SARC Path Receive AIS-P Insert Enable Indirect Data
(48 path)
are register configuration bits that individually enable or disable each defect. The bits
exist for each path. The RPAISINS is used to insert P-AIS on the receive SONET/SDH stream.
PAIS is inserted by inserting an all-ones pattern on the H1-H2 and the SPE bytes. Optionally, it
can be inserted on the transport overhead bytes.
Equation 6:
Alarm =
(RLAISINS
(MSRLAISINS AND MSRLAISINSEN
(PLOPTR
AND PLOPTREN
(PAISPTR
AND PAISPTREN
(PPLU AND PPLUEN
(PPLM AND PPLMEN
(PUNEQ
AND PUNEQEN
(PPDI AND PPDIEN
(PRDI AND PRDIEN
(PERDI AND PERDIEN
(PTIU AND PTIUEN
(PTIM AND PTIMEN
AND RLAISINSEN
) OR
) OR
) OR
) OR
) OR
) OR
) OR
) OR
) OR
) OR
)
) OR
The Path ERDI[2:0] insertion indication (PERDIINS) is defined in Table 23. A RDIEN bit
exists for each path. P-ERDI alarms are used to generate the receive in-band P-RDI alarm. They
are also used to return P-RDI to the far-end device.