PM5317 SPECTRA-9953 Telecom Standard Product Data Sheet
Release
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2000741, Issue 5
449
Register 2108H 2110H 2118H 2120H 2128H 2130H 2138H 2140H 2148H 2150H 2158H and
2160H: SHPI Pointer Interpreter Status
Bit
Type
Function
Default
Bit 15
Unused
Bit 14
Unused
Bit 13
Unused
Bit 12
Unused
Bit 11
Unused
Bit 10
Unused
Bit 9
Unused
Bit 8
Unused
Bit 7
Unused
Bit 6
Unused
Bit 5
R
PAISCV
X
Bit 4
R
PLOPCV
X
Bit 3
R
PAISV
X
Bit 2
R
PLOPV
X
Bit 1
Unused
X
Bit 0
Unused
X
The Pointer Interpreter Status Register is provided at SHPI Read/Write Address 2108H 2110H
2118H 2120H 2128H 2130H 2138H 2140H 2148H 2150H 2158H and 2160H.
PLOPV
The path lost of pointer state (PLOPV) bit indicates the current status of the pointer
interpreter state machine. PLOPV is set to logic 1 when the state machine is in the
LOP_state. PLOPV is set to logic 0 when the state machine is not in the LOP_state.
PAISV
The path alarm indication signal state (PAISV) bit indicates the current status of the pointer
interpreter state machine. PAISV is set to logic 1 when the state machine is in the
AIS_state. PAISV is set to logic 0 when the state machine is not in the AIS_state.
PLOPCV
The path lost of pointer concatenation state (PLOPCV) bit indicates the current status of the
concatenation pointer interpreter state machine. PLOPCV is set to logic 1 when the state
machine is in the LOPC_state. PLOPCV is set to logic 0 when the state machine is not in
the LOPC_state.