參數(shù)資料
型號(hào): AMD-8151
英文描述: AMD-8151 - Preliminary AMD-8151 HyperTransport AGP3.0 Graphics Tunnel Data Sheet
中文描述: AMD的8151 -初步的AMD - 8151 HyperTransport的AGP3.0圖形隧道數(shù)據(jù)表
文件頁(yè)數(shù): 91/378頁(yè)
文件大?。?/td> 3300K
代理商: AMD-8151
第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)當(dāng)前第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)第151頁(yè)第152頁(yè)第153頁(yè)第154頁(yè)第155頁(yè)第156頁(yè)第157頁(yè)第158頁(yè)第159頁(yè)第160頁(yè)第161頁(yè)第162頁(yè)第163頁(yè)第164頁(yè)第165頁(yè)第166頁(yè)第167頁(yè)第168頁(yè)第169頁(yè)第170頁(yè)第171頁(yè)第172頁(yè)第173頁(yè)第174頁(yè)第175頁(yè)第176頁(yè)第177頁(yè)第178頁(yè)第179頁(yè)第180頁(yè)第181頁(yè)第182頁(yè)第183頁(yè)第184頁(yè)第185頁(yè)第186頁(yè)第187頁(yè)第188頁(yè)第189頁(yè)第190頁(yè)第191頁(yè)第192頁(yè)第193頁(yè)第194頁(yè)第195頁(yè)第196頁(yè)第197頁(yè)第198頁(yè)第199頁(yè)第200頁(yè)第201頁(yè)第202頁(yè)第203頁(yè)第204頁(yè)第205頁(yè)第206頁(yè)第207頁(yè)第208頁(yè)第209頁(yè)第210頁(yè)第211頁(yè)第212頁(yè)第213頁(yè)第214頁(yè)第215頁(yè)第216頁(yè)第217頁(yè)第218頁(yè)第219頁(yè)第220頁(yè)第221頁(yè)第222頁(yè)第223頁(yè)第224頁(yè)第225頁(yè)第226頁(yè)第227頁(yè)第228頁(yè)第229頁(yè)第230頁(yè)第231頁(yè)第232頁(yè)第233頁(yè)第234頁(yè)第235頁(yè)第236頁(yè)第237頁(yè)第238頁(yè)第239頁(yè)第240頁(yè)第241頁(yè)第242頁(yè)第243頁(yè)第244頁(yè)第245頁(yè)第246頁(yè)第247頁(yè)第248頁(yè)第249頁(yè)第250頁(yè)第251頁(yè)第252頁(yè)第253頁(yè)第254頁(yè)第255頁(yè)第256頁(yè)第257頁(yè)第258頁(yè)第259頁(yè)第260頁(yè)第261頁(yè)第262頁(yè)第263頁(yè)第264頁(yè)第265頁(yè)第266頁(yè)第267頁(yè)第268頁(yè)第269頁(yè)第270頁(yè)第271頁(yè)第272頁(yè)第273頁(yè)第274頁(yè)第275頁(yè)第276頁(yè)第277頁(yè)第278頁(yè)第279頁(yè)第280頁(yè)第281頁(yè)第282頁(yè)第283頁(yè)第284頁(yè)第285頁(yè)第286頁(yè)第287頁(yè)第288頁(yè)第289頁(yè)第290頁(yè)第291頁(yè)第292頁(yè)第293頁(yè)第294頁(yè)第295頁(yè)第296頁(yè)第297頁(yè)第298頁(yè)第299頁(yè)第300頁(yè)第301頁(yè)第302頁(yè)第303頁(yè)第304頁(yè)第305頁(yè)第306頁(yè)第307頁(yè)第308頁(yè)第309頁(yè)第310頁(yè)第311頁(yè)第312頁(yè)第313頁(yè)第314頁(yè)第315頁(yè)第316頁(yè)第317頁(yè)第318頁(yè)第319頁(yè)第320頁(yè)第321頁(yè)第322頁(yè)第323頁(yè)第324頁(yè)第325頁(yè)第326頁(yè)第327頁(yè)第328頁(yè)第329頁(yè)第330頁(yè)第331頁(yè)第332頁(yè)第333頁(yè)第334頁(yè)第335頁(yè)第336頁(yè)第337頁(yè)第338頁(yè)第339頁(yè)第340頁(yè)第341頁(yè)第342頁(yè)第343頁(yè)第344頁(yè)第345頁(yè)第346頁(yè)第347頁(yè)第348頁(yè)第349頁(yè)第350頁(yè)第351頁(yè)第352頁(yè)第353頁(yè)第354頁(yè)第355頁(yè)第356頁(yè)第357頁(yè)第358頁(yè)第359頁(yè)第360頁(yè)第361頁(yè)第362頁(yè)第363頁(yè)第364頁(yè)第365頁(yè)第366頁(yè)第367頁(yè)第368頁(yè)第369頁(yè)第370頁(yè)第371頁(yè)第372頁(yè)第373頁(yè)第374頁(yè)第375頁(yè)第376頁(yè)第377頁(yè)第378頁(yè)
Chapter 3
Functional Operation
91
24674
Rev. 3.00
April 2003
AMD-8111 HyperTransport I/O Hub Data Sheet
AMD Preliminary Information
Transmit FIFO Underflow
Late collision errors can only occur when the device is operating in half-duplex mode. Loss of carrier
and transmit FIFO underflow errors are possible when the device is operating in half- or full-duplex
mode.
When a late collision or underflow error occurs in the middle of a multi-buffer frame transmission, the
appropriate error counter is incremented, and the transmission is aborted with an inverted FCS field
appended to the frame. The OWN bits in the current and subsequent descriptors are cleared until the
STP bit is found, indicating the start of the next frame.
If REX_UFLO (CMD2, bit 1) is set, the transmitter does not flush the frame data from the transmit
FIFO after a transmit FIFO underflow error occurs. Instead, it waits until the entire frame has been
copied into the transmit FIFO, and then it restarts the transmission process.
3.10.5.3.1 Loss of Carrier
The XmtLossCarrier counter is incremented if transmit is attempted when the LINK_STAT bit in the
STAT0 register is 0.
The LINK_STAT bit is set automatically during the auto-negotiation process when the external PHY
device determines that the link is up. Alternatively the software can bypass the auto-negotiation
process by clearing the EN_PMGR bit in CMD3 and setting FORCE_LINK_STATUS, also in
CMD3.
3.10.5.3.2 Late Collision
A late collision is detected when the device is operating in half-duplex mode and a collision condition
occurs after one slot time (512 bit times) after the transmit process was initiated (first bit of preamble
commenced). When it detects a late collision, the controller increments the XmtLateCollision
counter. The controller abandons the transmit process for that frame and processes the next transmit
frame in the ring.
3.10.5.3.3 Transmit FIFO Underflow
An underflow error occurs when the transmitter runs out of data from the transmit FIFO in the middle
of a transmission. When this happens, an inverted FCS is appended to the frame so that the intended
LAN Ethernet receiver will ignore the frame, and the XmtUnderrunPkts counter is incremented. If
REX_UFLO (CMD2, bit 1) is set to 1, the transmitter then waits until the entire frame has been
loaded into the transmit FIFO, and then it restarts the transmission of the same frame. If the
REX_UFLO is cleared to 0, the transmitter does not attempt to retransmit the aborted frame.
The REX_UFLO bit should not be set in a (nonstandard) system that allows frames that are larger
than the transmit FIFO size.
相關(guān)PDF資料
PDF描述
AMD64 AMD64 Architecture Programmer's Manual Volume 1: Application Programming
AMDATHLON AMD Athlon - AMD Athlon Processor Model 4 Revision Guide
AMDATHLON64 AMD Athlon 64 - Report of Management on Processor Performance Benchmarks AMD Athlon 64 Processor 3200+
AMDATHLONMP AMD Athlon MP - AMD Athlon MP Processor Model 6 Data Sheet
AMDATHLONXP AMD Athlon XP - AMD Athlon XP Processor Model 8 Data Sheet
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AMD-8151BLC 制造商:Advanced Micro Devices 功能描述:HyperTransport AGP3.0 Graphics Tunnel
AMD8255A-5 制造商:Advanced Micro Devices 功能描述:8255A-5
AMD8257 制造商:AMD 制造商全稱(chēng):Advanced Micro Devices 功能描述:Programmable DMA Controller
AMD850-N14BD 制造商:SMC Corporation of America 功能描述:MICRO MIST SEPARATOR W/ 1-1/4INCH PORTS
AMD8ATCBK 制造商:Wiremold / Legrand 功能描述:FLUSH POKE-THRU ASSY/BK/TC