第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)當(dāng)前第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)第151頁(yè)第152頁(yè)第153頁(yè)第154頁(yè)第155頁(yè)第156頁(yè)第157頁(yè)第158頁(yè)第159頁(yè)第160頁(yè)第161頁(yè)第162頁(yè)第163頁(yè)第164頁(yè)第165頁(yè)第166頁(yè)第167頁(yè)第168頁(yè)第169頁(yè)第170頁(yè)
MOTOROLA
Page 110
SECTION 15: MESSAGE DATA LINK CONTROLLER
MC68HC05V7 Specification Rev. 1.0
If the MDLC is transmitting a message and the message received contains invalid bits, or
framing symbols on non-byte boundaries, this constitutes a transmission error. When a
transmission error is detected, the MDLC will immediately cease transmitting.
If the MDLC is receiving a message and it detects an error during the message, the
message is discarded. No message with an error contained in it is passed to the CPU and
no error status information is available.
15.4.3.5.1
CRC Error
A CRC error is detected when the data bytes and CRC byte of a received message are
processed, and the CRC calculation result is not equal to $C4. The CRC code should
detect any single and 2 bit errors, as well as all 8 bit burst errors, and almost all other types
of errors.
15.4.3.5.2
Bit Format Error
A Bit Format error is detected when an abnormal (invalid) bit is detected in a message
being received from the J1850 bus. However, if the MDLC is transmitting when this
happens, it will be treated as a loss of arbitration rather than a transmitter error and the
automatic retry mechanism will apply.
15.4.3.5.3
Message Format Error
A Message Format error is detected if an EOD or EOF symbol is detected on a non-byte
boundary from the J1850 bus.
15.4.3.5.4
Bus Fault
If a bus fault occurs, the response of the MDLC will depend upon the type of bus fault.
If the bus is shorted to V
batt
, the MDLC will wait for the bus to fall to a passive state before
it will attempt to transmit a message. As long as the short remains, the MDLC will never
attempt to transmit a message onto the J1850 bus.
If the bus is shorted to ground, the MDLC will see an idle bus, begin to transmit the
message, and then detect a transmission error, since the short to ground would not allow
the bus to be driven to the dominant state. The MDLC will abort that transmission and wait
for the next CPU command to transmit.
In any case, if the bus fault is temporary, as soon as the fault is cleared, the MDLC will
resume normal operation. If the bus fault is permanent, it may result in permanent loss of
communication on the J1850 bus.
15.4.3.5.5
Message Under Length Error
Any message received by the MDLC must be at least two bytes long. Since the MDLC does
not have message filtering, these two bytes could just be one data byte and a CRC byte.
Any messages received with less than the minimum number of bytes will be discarded by
the MDLC.
15.4.3.5.6
Message Over Length Error
A Message Over Length error is detected when a message being received exceeds the
maximum length allowed for a message on the J1850 bus. If the Receive Block mode
(RXBM) bit is not set, the maximum received length from SOF to the EOD is 12 bytes
F
For More Information On This Product,
Go to: www.freescale.com
n
.
相關(guān)PDF資料
PDF描述
HC05 Bipolar Transistor; Transistor Polarity:Dual P Channel; Power Dissipation:20W; DC Current Gain Min (hfe):25; Collector Current:1A; DC Current Gain Max (hfe):200; Power (Ptot):20W
HC1-5502A-7 Subscriber Line Interface Circuit
HC4P-5502A-7 Subscriber Line Interface Circuit
HC1062A Low Voltage Telephone Speech Transmission Circuit / High/Low Level Mute
HC1198 Peripheral IC
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
HC060WE1DS038B 制造商:TE Connectivity 功能描述:EC7174-000
HC060YW1DS038B 制造商:TE Connectivity 功能描述:EC7207-000
HC06B05000J0G 制造商:FCI 功能描述:OEM ITEM 505-5BNF-SPRING CLAMP SYSTEM
HC08 制造商:Texas Instruments 功能描述:
HC08100 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Breake Away Header .025(0.64mm) Square Posts