2. If UDRI=1, then the FIFO has underrun and the last packet transmitted has been corrupted
and needs to be retransmitted. When the UDRI bit transitions to logic 1, one Abort sequence
and continuous flags will be transmitted. The TDPR FIFO is held in reset state. To re-enable
the TDPR FIFO and to clear the underrun, the TDPR Interrupt Status/UDR Clear register
should be written with any value.
3. If OVRI=1, then the FIFO has overflowed. The packet which the last byte written into the
FIFO belongs to has been corrupted and must be retransmitted. Other packets in the FIFO are
not affected. Either a timer can be used to determine when sufficient bytes are available in
the FIFO or the user can wait until the LFILLI interrupt is set, indicating that the FIFO depth
is at the lower threshold limit.
If the FIFO overflows on the packet currently being transmitted (packet is greater than 128
bytes long), OVRI is set, an Abort signal is scheduled to be transmitted, the FIFO is emptied,
and then flags are continuously sent until there is data to be transmitted. The FIFO is held in
reset until a write to the TDPR Transmit Data register occurs. This write contains the first
byte of the next packet to be transmitted.
4. If FULLI=1 and FULL=1, then the TDPR FIFO is full and no further bytes can be written.
When in this state, either a timer can be used to determine when sufficient bytes are available
in the FIFO or the user can wait until the LFILLI interrupt is set, indicating that the FIFO
depth is at the lower threshold limit.
If FULLI=1 and FULL=0, then the TDPR FIFO had reached the FULL state earlier, but has
since emptied out some of its data bytes and now has space available in its FIFO for more
data.
5. If LFILLI=1 and BLFILL=1, then the TDPR FIFO depth is below its lower threshold limit.
If there is more data to transmit, then it should be written to the TDPR Transmit Data register
before an underrun occurs. If there is no more data to transmit, then an EOM should be set at
the end of the last packet byte. Flags will then be transmitted once the last packet has been
transmitted.
If LFILLI=1 and BLFILL=0, then the TDPR FIFO had fallen below the lower-threshold state
earlier, but has since been refilled to a level above the lower-threshold level.
Polling Mode
The TDPR automatically transmits a packet once it is completely written into the TDPR FIFO.
The TDPR also begins transmission of bytes once the FIFO level exceeds the programmable
Upper Transmit Threshold. The CRC bit can be set to logic 1 so that the FCS is generated and
inserted at the end of a packet. The TDPR Lower Interrupt Threshold should be set to such a
value that sufficient warning of an underrun is given. The FULLE, LFILLE, OVRE, and UDRE
bits are all set to logic 0 since packet transmission is set to work with a periodic polling
procedure. The following procedure should be followed to transmit HDLC packets:
1. Wait until data is available to be transmitted, then go to step 2.