STANDARD PRODUCT
PM8315 TEMUX
DATASHEET
PMC-1981125
ISSUE 7
HIGH DENSITY T1/E1 FRAMER  WITH
INTEGRATED VT/TU MAPPER AND M13 MUX
PROPRIETARY AND CONFIDENTIAL
221
Table 27
- T1 Channel Associated Signaling bits
SF
ESF
S
1
S
2
S
3
S
4
F
F
P
1
 P
0
A1
A2
A3
A4
F1
M1
00
A5
A6
A7
A8
S1
C1
00
A9
A10
A11
A12
F2
M2
00
A13
A14
A15
A16
S2
F1
00
A17
A18
A19
A20
F3
M3
00
A21
A22
A23
A24
S3
C2
00
B1
B2
B3
B4
F4
M4
01
B5
B6
B7
B8
S4
F2
01
B9
B10
B11
B12
F5
M5
01
B13
B14
B15
B16
S5
C3
01
B17
B18
B19
B20
F6
M6
01
B21
B22
B23
B24
S6
F3
01
C1
C2
C3
C4
F1
M7
10
C5
C6
C7
C8
S1
C4
10
C9
C10
C11
C12
F2
M8
10
C13
C14
C15
C16
S2
F4
10
C17
C18
C19
C20
F3
M9
10
C21
C22
C23
C24
S3
C5
10
D1
D2
D3
D4
F4
M10
11
D5
D6
D7
D8
S4
F5
11
D9
D10
D11
D12
F5
M11
11
D13
D14
D15
D16
S5
C6
11
D17
D18
D19
D20
F6
M12
11
D21
D22
D23
D24
S6
F6
11
Note that in synchronous mode, the SF/ESF F-bits may have arbitrary alignment
with respect to the P
1
P
0
 phase alignment bits, due to possible frame slips at the
T1 level.  However, CAS is always aligned to the P
1
P
0
 bits (i.e. in either
synchronous or asynchronous mode).
T1 tributary asynchronous timing is compensated via the V3 octet. T1 tributary
link rate adjustments are optionally passed across the SBI via  the V4. T1
tributary alarm conditions are optionally passed across the SBI bus via the link
rate octet in the V4 location.
In synchronous mode the T1 tributary mapping is fixed to that shown in Table 26
and rate justifications are not possible using the V3 octet. The clock rate
information within the link rate octet in the V4 location is not used in synchronous
mode.