13. CardBus PC Card Terminals (Slots A and B)
TERMINAL
NUMBER
I/O
DESCRIPTION
NAME
SLOT A
PDV
SLOT B
PDV
GHK
GHK
CAUDIO
140
H17
72
V09
I
CardBus audio. CAUDIO is a digital input signal from a PC Card to the system speaker.
The PCI1620 supports the binary audio mode and outputs a binary signal from the card to
SPKROUT.
CBLOCK
108
N14
41
N03
I/O
CardBus lock. CBLOCK is used to gain exclusive access to a target.
CCD1
CCD2
83
144
U11
G18
15
75
H05
P09
I
The card-detect terminals and the voltage-sense terminals are used together to determine
the insertion event and type of PC Card inserted (16-bit, CardBus, or UltraMedia). The
PCI1620 implements changes in the interrogation logic that handles this function. See
Section NO TAG,
PC Card Insertion/Removal and Recognition
, for more information.
CDEVSEL
113
N15
46
P03
I/O
CardBus device select. The PCI1620 asserts CDEVSEL to claim a CardBus cycle as the
target device. As a CardBus initiator on the bus, the PCI1620 monitors CDEVSEL until a
target responds. If no target responds before timeout occurs, then the PCI1620 terminates
the cycle with an initiator abort.
CFRAME
119
M15
51
R03
I/O
CardBus cycle frame. CFRAME is driven by the initiator of a CardBus bus cycle. CFRAME
is asserted to indicate that a bus transaction is beginning, and data transfers continue while
this signal is asserted. When CFRAME is deasserted, the CardBus bus transaction is in
the final data phase.
CGNT
112
P18
45
N05
O
CardBus bus grant. CGNT is driven by the PCI1620 to grant a CardBus PC Card access
to the CardBus bus after the current data transaction has been completed.
CINT
138
H19
69
V08
I
CardBus interrupt. CINT is asserted low by a CardBus PC Card to request interrupt
servicing from the host.
CIRDY
117
N18
50
P05
I/O
CardBus initiator ready. CIRDY indicates the ability of the CardBus initiator to complete the
current data phase of the transaction. A data phase is completed on a rising edge of CCLK
when both CIRDY and CTRDY are asserted. Until CIRDY and CTRDY are both sampled
asserted, wait states are inserted.
CPERR
109
R18
42
N06
I/O
CardBus parity error. CPERR reports parity errors during CardBus transactions, except
during special cycles. It is driven low by a target two clocks following the data cycle when
a parity error is detected.
CREQ
130
K17
61
R07
I
CardBus request. CREQ indicates to the arbiter that the CardBus PC Card desires use of
the CardBus bus as an initiator.
CSERR
139
H18
71
W09
I
CardBus system error. CSERR reports address parity errors and other system errors that
could lead to catastrophic results. CSERR is driven by the card synchronous to CCLK, but
deasserted by a weak pullup, and deassertion may take several CCLK periods. The
PCI1620 can report CSERR to the system by assertion of SERR on the PCI interface.
CSTOP
111
P17
44
P02
I/O
CardBus stop. CSTOP is driven by a CardBus target to request the initiator to stop the
current CardBus transaction. CSTOP is used for target disconnects, and is commonly
asserted by target devices that do not support burst data transfers.
CSTSCHG
141
H14
73
U09
I
CardBus status change. CSTSCHG alerts the system to a change in the card status, and
is used as a wake-up mechanism.
CTRDY
116
N17
49
R02
I/O
CardBus target ready. CTRDY indicates the ability of the CardBus target to complete the
current data phase of the transaction. A data phase is completed on a rising edge of CCLK,
when both CIRDY and CTRDY are asserted; until this time, wait states are inserted.
CVS1
CVS2
137
124
J14
L14
68
56
U08
P07
I/O
The card-detect terminals and the voltage-sense terminals are used together to determine
the insertion event and type of PC Card inserted (16-bit, CardBus, or UltraMedia). The
PCI1620 implements changes in the interrogation logic that handles this function.
Terminal name for slot A is preceded with A_. For example, the full name for terminals 140 and H17 are A_CAUDIO.
Terminal name for slot B is preceded with B_. For example, the full name for terminals 72 and V09 are B_CAUDIO.