www.national.com
84
A/D Converter Characteristics
Icca1
Iccprog
Icca2
Icca1
Iccprog
Icca2
Iccps
Iccid
Iccq
Iacc
a. Guaranteed by design.
b. Hysteresis applies only when the Schmitt trigger is enabled or when alternate function is selected.
c. Running from internal memory, Iout = 0 mA, XCKI1 = 20 and 8 MHz, not programming flash memory.
d. Same conditions as c. (Icca1), but while programming or erasing one of the flash memory arrays.
e. CPU executing an WAIT instruction, Iout = 0 mA, XCKI1 = 20 and 8 MHz, peripherals not active.
f. Running from internal memory, Iout = 0mA, Iout = 0mA, XCKI1 = 20 MHz, XCKI2 = 32.768 kHz.
g. Iout = 0mA, XCKI1 = Vcc, X2CKI = 32.768 kHz
h. Same conditions as g. (Iccps), but in Halt mode instead of Idle mode
i. A/D converter and analog comparators enabled.
j. I
L
and I
O
are 2.0
μ
A at 85°C and 5.0
μ
A at 125°C
k. I
acq
is 20
μ
A at 85°C and 50
μ
A at 125°Ci.
i.
Digital Supply Current Active Mode, normal
c
Digital Supply Current Active Mode, flash mem.
d
Digital Supply Current Active Mode, WAIT
e
Digital Supply Current Active Mode, normal
c
Digital Supply Current Active Mode, flash mem.
d
Digital Supply Current Active Mode, WAIT
e
Digital Supply Current Power Save Mode
f
Digital Supply Current Idle Mode
g
Digital Supply Current Halt Mode
h
Analog Supply Current Active Mode
i
TC = 20 MHz, Vcc= 5.5V
TC = 20 MHz, Vcc = 5.5V
TC = 20 MHz, Vcc = 5.5V
TC = 8 MHz, Vcc= 5.5V
TC = 8 MHz, Vcc = 5.5V
TC = 8 MHz, Vcc = 5.5V
Vcc= 5.5V
Vcc = 5.5V
Vcc = 5.5V
Vcc = 5.5V
38
46
23.2
38
46
23.2
9
60
15
k
3
mA
mA
mA
mA
mA
mA
mA
μ
A
μ
A
mA
Symbol
Parameter
Conditions
a
a. All parameters specified for f
OSC
= 1 MHz,
V
DD
= 5.0V
±
10%, V
DD
= 5.0V
±
10% unless otherwise noted.
b. Integral (non-linearity) error; the maximum difference between the best-fit straight line reference and the actual
conversion curve.
c. Differential (non-linearity) error; the maximum difference between the best-fit stair-step reference with 1-LSB
resolution and the actual conversion curve.
d. The resistance between the device input and the internal analog input capacitance.
e. The input signal is measured across the internal capacitance.
Min
Typ
Max
Units
N
IL
N
DL
V
IN
V
REFEX
V
REFI
I
VREF
I
AL
R
AIN
C
AIN
Integral Error
b
Differential Error
c
V
REF
= V
CC
V
REF
= V
CC
V
REF
<
V
CC
- 0.1
1
LSB
1
LSB
Input Voltage Range
0
V
REF
V
DD
2.625
V
External Reference Voltage
3.0
V
Internal Reference Voltage
2.375
2.5
V
V
REF
input current
Analog input leakage current
Analog input resistance
d
Analog input capacitance
e
V
REF
= 5 V
V
REF
= V
CC
1.0
mA
±
1
μ
A
200
5
pF
tADCCLK
C
REFEX
t
ACT
Conversion Clock period
1
μ
s
μ
F
μ
sec
External Vref bypass capacitance
0.47
First A/D conversion after Vcc stable
100
Symbol
Parameter
Conditions
Min
Max
Units