560
Table 25-21 Absolute Maximum Ratings (HD404358 and HD404358R Series)
HD404358 Series
HD404358R Series
Item
Symbol Rated Value
Rated Value
Unit Notes
Power supply voltage
V
CC
–0.3 to +7.0
V
Programming voltage
V
PP
–0.3 to +14.0
V
1
Pin voltage
V
T
–0.3 to V
CC + 0.3
–0.3 to V
CC + 0.3
V
2
–0.3 to +15.0
—
V3
Allowable total input current
(current flowing in to the LSI)
∑I
0
105
160
mA
4
Allowable total output current
(current flowing out from the LSI)
–
∑I
0
50
mA
5
Allowable input current
I
0
4
mA
6, 7
(current flowing in to the LSI)
30
mA
6, 8
Allowable output current
(current flowing out from the LSI)
–I
0
4
mA
9, 10
Operating temperature
T
opr
–20 to +75
°C
Storage temperature
T
stg
–55 to +125
°C
Notes: 1. Applies to the HD407A4359, HD407A4359R, and HD407C4359R TEST (V
PP) pin.
2. Applies to all standard pins.
3. Applies to the medium voltage pins.
4. The allowable total input current is the sum of the currents flowing from all the I/O pins
to ground at the same time.
5. The allowable total output current is the sum of the currents flowing from V
CC to all the
I/O pins at the same time.
6. The allowable input current is the maximum value of the currents flowing from each I/O
pin to ground.
7. HD404358 Series:
Applies to D
0 to D8, R0, R1, R3, R4, and R8.
HD404358R Series: Applies to D
0 to D4, R3, and R4.
8. HD404358 Series:
Applies to R2.
HD404358R Series: Applies to D
5 to D8, R0, R1, R2, and R8.
9. HD404358 Series:
Applies to D
0 to D8, R0, R1, R3, R4, and R8.
HD404358R Series: Applies to D
0 to D8, R0, R1, R2, R3, R4, and R8.
10. The allowable output current is the maximum value of the currents flowing from V
CC to
each I/O pin.
Use of this LSI at levels that exceed the absolute maximum ratings can permanently
damage the LSI. Also note that it is desirable to use this LSI within the conditions specified
in the “Electrical Characteristics” section during normal operation. Exceeding those
conditions can cause the LSI to operate incorrectly and may adversely affect LSI reliability.
All voltage values are referenced to ground.