TMXF28155 Supermapper
155/51 Mbits/s SONET/SDH x28/x21 DS1/E1
Data Sheet
June 2002
124
Agere Systems Inc.
8 TMUX Registers
(continued)
Table 144. TMUX_RJ1EXPECTED1_[1—32], Expected J1 Byte Value for Port 1 (R/W)
Table 145. TMUX_RJ1EXPECTED2_[1—32], Expected J1 Byte Value for Port 2 (R/W)
Table 146. TMUX_RJ1EXPECTED3_[1—32], Expected J1 Byte Value for Port 3 (R/W)
Table 147. TMUX_RJ1CAPTURED1_[1—32], Captured J1 Value for STS #1 (RO)
Table 148. TMUX_RJ1CAPTURED2_[1—32], Captured J1 Value for STS #2 (RO)
Table 149. TMUX_RJ1CAPTURED3_[1—32], Captured J1 Value for STS #3 (RO)
Address
Bit
Name
Function
Reset
Default
0x0000
0x400E0
—
0x400FF
15:0
TMUX_EXPJ1DMON1[64—1][7:0]
Expected Receive J1 Value for Port 1.
Reg-
isters contain either the programmed
expected J1 16-byte/64-byte sequence or the
previously captured J1 sequence, depending
on the J1 mode.
Address
Bit
Name
Function
Reset
Default
0x0000
0x40100
—
0x4011F
15:0
TMUX_EXPJ1DMON2[64—1][7:0]
Expected Receive J1 Value for Port 2.
Reg-
isters contain either the programmed
expected J1 16-byte/64-byte sequence or the
previously captured J1 sequence, depending
on the J1 mode.
Address
Bit
Name
Function
Reset
Default
0x0000
0x40120
—
0x4013F
15:0 TMUX_EXPJ1DMON3[64—1][7:0]
Expected Receive J1 Value for Port 3.
Regis-
ters contain either the programmed expected
J1 16-byte/64-byte sequence or the previously
captured J1 sequence, depending on the J1
mode.
Address
Bit
Name
Function
Reset
Default
0x0000
0x40140
—
0x4015F
15:0
TMUX_J1DMON1[64—1][7:0]
Receive J1 Monitor Data for Port 1.
Registers
capture a 16-byte/64-byte sequence from the port
1, J1 byte of the STS-3/STM-1 (AU-4) input signal.
Only port 1 information is valid in AU-4 mode.
Address
Bit
Name
Function
Reset
Default
0x0000
0x40160
—
0x4017F
15:0
TMUX_J1DMON2[64—1][7:0]
Receive J1 Monitor Data for Port 2.
Registers
capture a 64-byte sequence from the port 2, J1 byte
of the STS-3/STM-1 (AU-4) input signal.
Only port 1
information is valid in AU-4 mode.
Address
Bit
Name
Function
Reset
Default
0x0000
0x40180
—
0x4019F
15:0
TMUX_J1DMON3[64—1][7:0]
Receive J1 Monitor Data for Port 3.
Registers
capture a 64-byte sequence from the port 3 J1
byte of the STS-3/STM-1 (AU-4) input signal.
Only port 1 information is valid in AU-4 mode.