![](http://datasheet.mmic.net.cn/170000/S71PL191HB0BFI100_datasheet_9723326/S71PL191HB0BFI100_124.png)
28
S29JL064H
S29JL064HA1 May 7, 2004
Pr el i m i n ary
If DQ5 goes high during a program or erase operation, writing the reset command
returns the banks to the read mode (or erase-suspend-read mode if that bank
was in Erase Suspend).
Autoselect Command Sequence
The autoselect command sequence allows the host system to access the manu-
facturer and device codes, and determine whether or not a sector is protected.
The autoselect command sequence may be written to an address within a bank
that is either in the read or erase-suspend-read mode. The autoselect command
may not be written while the device is actively programming or erasing in another
bank.
The autoselect command sequence is initiated by first writing two unlock cycles.
This is followed by a third write cycle that contains the bank address and the au-
toselect command. The bank then enters the autoselect mode. The system may
read any number of autoselect codes without reinitiating the command sequence.
Table 4 shows the address and data requirements. To determine sector protection
information, the system must write to the appropriate bank address (BA) and
sector address (SA).
Table 3 shows the address range and bank number associ-
ated with each sector.
The system must write the reset command to return to the read mode (or erase-
suspend-read mode if the bank was previously in Erase Suspend).
Enter SecSi Sector/Exit SecSi Sector
Command Sequence
The SecSi Sector region provides a secured data area containing a random, six-
teen-byte electronic serial number (ESN). The system can access the SecSi
Sector region by issuing the three-cycle Enter SecSi Sector command sequence.
The device continues to access the SecSi Sector region until the system issues
the four-cycle Exit SecSi Sector command sequence. The Exit SecSi Sector com-
mand sequence returns the device to normal operation. The SecSi Sector is not
accessible when the device is executing an Embedded Program or embedded
Erase algorithm.
Table 4 shows the address and data requirements for both com-
lock bypass modes are not available when the SecSi Sector is enabled.
Byte/Word Program Command Sequence
The system may program the device by word or byte, depending on the state of
the BYTE# pin. Programming is a four-bus-cycle operation. The program com-
mand sequence is initiated by writing two unlock write cycles, followed by the
program set-up command. The program address and data are written next, which
in turn initiate the Embedded Program algorithm. The system is not required to
provide further controls or timings. The device automatically provides internally
generated program pulses and verifies the programmed cell margin.
Table 4shows the address and data requirements for the byte program command
sequence.
When the Embedded Program algorithm is complete, that bank then returns to
the read mode and addresses are no longer latched. The system can determine
the status of the program operation by using DQ7, DQ6, or RY/BY#. Refer to the