![](http://datasheet.mmic.net.cn/330000/PM7325_datasheet_16444376/PM7325_97.png)
S/UNI-ATLAS-3200 Telecom Standard Product Data Sheet
Preliminary
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990553, Issue 4
97
Table 20 Actions on Policing with COCUP=1
GCRA2
Fail
GCRA1
Pass
No Action
Tag
Discard
Pass
Update TAT1
Update TAT2
Update TAT1
Update TAT1
No Update
No Action
Update TAT2
No Update
No Update
No Update
Tag
Update TAT2
No Update
No Update
No Update
Fail
Discard
No Update
No Update
No Update
No Update
In both cases (COCUP=1 and COCUP=0), if a cell fails both GCRA1 and GCRA2, the most
severe action is taken on the cell.
The three 16-bit non-compliant counts are programmed in either the NCOUNTx[3:0] or the
GFR_NCOUNTx[3:0] fields of the Per-VC Non-Compliant Cell Counting Configuration,
depending on whether the GFR bit is set to logic 1 in the policing configuration field of the VC
table. Each non-compliant count has the following programming options:
Table 21 Non-Compliant Cell Count Configurations
NCOUNTx[3:0]
Definition
0000
Non-compliant CLP=0 cells.
0001
Non-compliant CLP=0+1 cells.
0010
Discarded CLP=0 cells.
0011
Discarded CLP=0+1 cells.
0100
Tagged CLP=0 cells which are not discarded
0101
Non-compliant CLP=0 frames (GFR only)
0110
Non-compliant CLP=0+1 frames (GFR only)
0111
Partially or Completely Discarded CLP=0 frames (GFR Only)
1000
Partially or Completely Discarded CLP=0+1 frames (GFR Only)
1001
Tagged CLP=0 Frames which are not discarded (GFR Only)
1010
Total CLP=0 AAL5 Frames Received
1011
Total CLP=0+1 AAL5 Frames Received
1100
Total cells non-compliant to GCRA1
1101
Total cells non-compliant to GCRA2
1110
Total cells non-compliant to the PHY GCRA
1111
Reserved
The Total AAL5 Frames Received counts are available in non-GFR connections, but the other
frame-aware counts should not be selected except in the GFR case. Counting of CLP0 vs. CLP 1
frames is based on the CLP of the received EOP.
These non-compliant cell counts may, for instance, be programmed to satisfy the following