Stable
Inputs stable at a HIGH or LOW level
Floating
Inputs at VREF = VDDQ/2
Switching Inputs changing between HIGH and LOW every other clock cycle (once per
two clocks) for address and control signals
Switching Inputs changing between HIGH and LOW every other data transfer (once
per clock) for DQ signals, not including masks or strobes
6. IDD1, IDD4R, and IDD7 require A12 in EMR to be enabled during testing.
7. The following IDD values must be derated (IDD limits increase) on IT-option and AT-op-
tion devices when operated outside of the range 0°C
≤ TC ≤ 85°C:
When
TC ≤ 0°C
IDD2P and IDD3P(SLOW) must be derated by 4%; IDD4R and IDD5W must be derat-
ed by 2%; and IDD6 and IDD7 must be derated by 7%
When
TC ≥ 85°C
IDD0, IDD1, IDD2N, IDD2Q, IDD3N, IDD3P(FAST), IDD4R, IDD4W, and IDD5W must be derat-
ed by 2%; IDD2P must be derated by 20%; IDD3P(SLOW) must be derated by
30%; and IDD6 must be derated by 80% (IDD6 will increase by this amount if
TC < 85°C and the 2X refresh option is still enabled)
1Gb: x4, x8, x16 1.55V DDR2 SDRAM
Electrical Specifications – IDD Parameters
PDF: 09005aef82b91d01
1GbDDR2_1_55V.PDF Rev. A 5/09 EN
28
Micron Technology, Inc. reserves the right to change products or specifications without notice.
2009 Micron Technology, Inc. All rights reserved.