396
Bit 2—Transmit End (TEND): Indicates that there is no valid data in TDR when the last bit of
the transmit character is sent, and transmission has been ended.
The TEND flag is read-only and cannot be modified.
Bit 2
TEND
Description
0
[Clearing conditions]
When 0 is written in TDRE after reading TDRE = 1
When the DTC is activated by a TXI interrupt and writes data to TDR
1
[Setting conditions]
(Initial value)
When the TE bit in SCR is 0
When TDRE = 1 at transmission of the last bit of a 1-byte serial transmit
character
Bit 1—Multiprocessor Bit (MPB): When reception is performed using a multiprocessor format
in asynchronous mode, MPB stores the multiprocessor bit in the receive data.
MPB is a read-only bit, and cannot be modified.
Bit 1
MPB
Description
0
[Clearing condition]
(Initial value)*
When data with a 0 multiprocessor bit is received
1
[Setting condition]
When data with a 1 multiprocessor bit is received
Note: * Retains its previous state when the RE bit in SCR is cleared to 0 with multiprocessor
format.
Bit 0—Multiprocessor Bit Transfer (MPBT): When transmission is performed using a
multiprocessor format in asynchronous mode, MPBT stores the multiprocessor bit to be added to
the transmit data.
The MPBT bit setting is invalid when a multiprocessor format is not used, when not
transmitting, and in synchronous mode.
Bit 0
MPBT
Description
0
Data with a 0 multiprocessor bit is transmitted
(Initial value)
1
Data with a 1 multiprocessor bit is transmitted