參數資料
型號: XBIB-U
廠商: Digi International/Maxstream
文件頁數: 38/72頁
文件大?。?/td> 1116K
描述: BOARD USB ZIGBEE MOD PRO
設計資源: XBIB-U Shematic
標準包裝: 1
附件類型: 接口板
適用于相關產品: XBee 和 XBee Pro 收音機
XBee/XBeePRO"燨EM燫F燤odules??02.15.4?爒1.xAx燵2007.05.031]
2007燤axStream,營nc.
牋牋?8
Chapter??燫F燤odule燙onfiguration
CC (Command Sequence Character) Command
<AT Command Mode Options> The CC command
is used to set and read the ASCII character used
between guard times of the AT Command Mode
Sequence (GT + CC + GT). This sequence enters
the RF module into AT Command Mode so that
data entering the module from the host is recog-
nized as commands instead of payload.
The AT Command Sequence is explained further in the AT Command Mode section.
CE (Coordinator Enable) Command
<Serial Interfacing> The CE command is used to
set and read the behavior (End Device vs. Coordi-
nator) of the RF module.
CH (Channel) Command
<Networking {Addressing}> The CH command is
used to set/read the operating channel on which
RF connections are made between RF modules.
The channel is one of three addressing options
available to the module. The other options are the
PAN ID (ID command) and destination addresses
(DL & DH commands).
In order for modules to communicate with each
other, the modules must share the same channel
number. Different channels can be used to prevent modules in one network from listening to trans-
missions of another. Adjacent channel rejection is 23 dB.
The module uses channel numbers of the 802.15.4 standard.
Center Frequency = 2.405 + (CH - 11d) * 5 MHz
(d = decimal)
Refer to the XBee/XBee-PRO Addressing section for more information.
CN (Exit Command Mode) Command
<AT Command Mode Options> The CN command
is used to explicitly exit the RF module from AT
Command Mode.
CT (Command Mode Timeout) Command
<AT Command Mode Options> The CT command
is used to set and read the amount of inactive
time that elapses before the RF module automati-
cally exits from AT Command Mode and returns to
Idle Mode.
Use the CN (Exit Command Mode) command to
exit AT Command Mode manually.
AT Command: ATCC
Parameter Range: 0 - 0xFF
Default Parameter Value: 0x2B (ASCII +)
Related Command: GT (Guard Times)
AT Command: ATCE
Parameter Range:0 - 1
Parameter
Configuration
0
End Device
1
Coordinator
Default Parameter Value:0
Minimum Firmware Version Required: v1.x80
AT Command: ATCH
Parameter Range: 0x0B - 0x1A (XBee)
 0x0C - 0x17 (XBee-PRO)
Default Parameter Value: 0x0C (12 decimal)
Related Commands: ID (PAN ID), DL
(Destination Address Low, DH (Destination
Address High)
AT Command: ATCN
AT Command: ATCT
Parameter Range:2 - 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0x64 (100 decimal
(which equals 10 decimal seconds))
Number of bytes returned: 2
Related Command: CN (Exit Command Mode)
相關PDF資料
PDF描述
XIB-E BOARD INTERFACE ETHERNET
XIB-R BOARD INTERFACE RS232/485
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
相關代理商/技術參數
參數描述
XBIB-U-DEV 功能描述:界面開發(fā)工具 USB XBee-PRO profes onal interface board RoHS:否 制造商:Bourns 產品:Evaluation Boards 類型:RS-485 工具用于評估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
XBIB-U-SP 功能描述:界面開發(fā)工具 USB/Xbee/Xbee-Pro Inf Brd SMT Pads RoHS:否 制造商:Bourns 產品:Evaluation Boards 類型:RS-485 工具用于評估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
XBIB-U-SS 功能描述:界面開發(fā)工具 USB/Xbee/Xbee-Pro Inf Brd SMT Skt RoHS:否 制造商:Bourns 產品:Evaluation Boards 類型:RS-485 工具用于評估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
XBL6450BYFVR 制造商:Texas Instruments 功能描述:ECS BLUELINK - Tape and Reel
XBL6450YFHR 制造商:Texas Instruments 功能描述: