3.燫F燤odule燙onfiguration
3.1. Programming the RF Module
Refer to the Command Mode section [p24] for more information about entering Command Mode,
sending AT commands and exiting Command Mode. For information regarding module program-
ming using API Mode, refer to the API Operation sections [p54].
3.1.1. Programming Examples
Setup
Sample Configuration: Modify RF Module Destination Address
Sample Configuration: Restore RF Module Defaults
The programming examples in this section require the installation of MaxStream's X-CTU Soft-
ware and a serial connection to a PC. (MaxStream stocks RS-232 and USB boards to facilitate
interfacing with a PC.)
1.   Install MaxStream's X-CTU Software to a PC by double-clicking the "setup_X-CTU.exe" file.
(The file is located on the MaxStream CD and under the 'Software' section of the following
web page: www.maxstream.net/support/downloads.php)
2.   Mount the RF module to an interface board, then connect the module assembly to a PC.
3.   Launch the X-CTU Software and select the 'PC Settings' tab. Verify the baud and parity set-
tings of the Com Port match those of the RF module.
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch.
Ensure the Baud setting on the PC Settings tab matches the interface data rate of the RF mod-
ule. By default, the BD parameter = 3 (which corresponds to 9600 bps).
Example: Utilize the X-CTU Terminal tab to change the RF module's DL (Destination Address
Low) parameter and save the new address to non-volatile memory.
After establishing a serial connection between the RF module and a PC [refer to the 'Setup' sec-
tion above], select the Terminal tab of the X-CTU Software and enter the following command
lines (CR stands for carriage return):
Method 1 (One line per command)
Send AT Command
+++
ATDL
ATDL1A0D
ATWR
ATCN
System Response
OK (Enter into Command Mode)
{current value} (Read Destination Address Low)
OK (Modify Destination Address Low)
OK (Write to non-volatile memory)
OK (Exit Command Mode)
Method 2 (Multiple commands on one line)
Send AT Command
+++
ATDL
ATDL1A0D,WR,CN
System Response
OK (Enter into Command Mode)
{current value} (Read Destination Address Low)
OK OK OK
Example: Utilize the X-CTU Modem Configuration tab to restore default parameter values.
After establishing a connection between the module and a PC [refer to the 'Setup' section
above], select the Modem Configuration tab of the X-CTU Software.
1. Select the 'Read' button.
2. Select the 'Restore' button.
Refer爐o爐he?XCTU爏ec
tion爋f爐he燚evelop
ment燝uide燵Appendix?/DIV>
B]爁or爉ore爄nformation?/DIV>
regarding爐he燲CTU?/DIV>
configuration爏oftware.
相關(guān)代理商/技術(shù)參數(shù) |
參數(shù)描述 |
XBIB-U-DEV |
功能描述:界面開(kāi)發(fā)工具 USB XBee-PRO profes onal interface board
RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類(lèi)型:RS-485 工具用于評(píng)估:ADM3485E 接口類(lèi)型:RS-485 工作電源電壓:3.3 V |
XBIB-U-SP |
功能描述:界面開(kāi)發(fā)工具 USB/Xbee/Xbee-Pro Inf Brd SMT Pads
RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類(lèi)型:RS-485 工具用于評(píng)估:ADM3485E 接口類(lèi)型:RS-485 工作電源電壓:3.3 V |
XBIB-U-SS |
功能描述:界面開(kāi)發(fā)工具 USB/Xbee/Xbee-Pro Inf Brd SMT Skt
RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類(lèi)型:RS-485 工具用于評(píng)估:ADM3485E 接口類(lèi)型:RS-485 工作電源電壓:3.3 V |
XBL6450BYFVR |
制造商:Texas Instruments 功能描述:ECS BLUELINK - Tape and Reel |
XBL6450YFHR |
制造商:Texas Instruments 功能描述: |