6.1.2 Register1: Status Register 
RTL8305SB 
2002/04/09 
23
Rev.1.0
 Reg.bit 
 1.15 
 1.14 
 Name 
 100Base_T4 
 100Base_TX_FD 
 Description 
 0: No 100Base-T4 capability. 
 1: 100Base-TX full duplex capable. 
 0: Not 100Base-TX full duplex capable. 
 1: 100Base-TX half duplex capable. 
 0: Not 100Base-TX half duplex capable. 
 1: 10Base-TX full duplex capable. 
 0: Not 10Base-TX full duplex capable. 
 1: 10Base-TX half duplex capable. 
 0: Not 10Base-TX half duplex capable. 
 The RTL8305SB will accept management frames with 
preamble suppressed. 
 Mode 
 RO 
 RO 
Default 
0 
1 
 1.13 
 100Base_TX_HD 
 RO 
1 
 1.12 
 10Base_T_FD 
 RO 
1 
 1.11 
 10Base_T_HD 
 RO 
1 
 1.[10:7] 
 1.6 
 Reserved 
 MF Preamble 
 Suppression 
 RO 
 RO 
0 
1 
 The RTL8305SB accepts management frames without 
preamble. Minimum of 32 preamble bits are required for the 
first SMI read/write transaction after reset. One idle bit is 
required between any two management transactions as defined 
in IEEE802.3u specs. 
 1: Auto-negotiation process completed. MII Reg.4,5 are valid 
if this bit is set. 
 0: Auto-negotiation process not completed. 
 1: Remote fault condition detected. 
 0: No remote fault.  
 When in 100FX mode, this bit means in-band signal 
Far-End-Fault is detected. 
 1: Nway auto-negotiation capable. (permanently: 1) 
 1: Link is established. If link had ever failed, this bit will be 0 
until after reading this bit again. 
 0: Link is failed. 
 0: No Jabber detected. 
 1.5 
 Auto-negotiate 
 Complete 
 RO 
0 
 1.4 
 Remote Fault 
 RO/LH 
0 
 1.3 
 Auto-Negotiation 
 Ability 
 Link Status 
 RO 
1 
 1.2 
 RO/LL 
0 
 1.1 
 Jabber Detect 
 Note: this function is not necessary for single chip. 
 Extended Capability  1: Extended register capable. (permanently: 1) 
6.1.3 Register4: Auto-Negotiation Advertisement Register 
 RO 
0 
 1.0 
 RO 
1 
 Reg.bit 
 4.15 
 Name 
 Next Page 
 Description 
 1: Next Page enabled. 
 0: Next Page disabled. (Permanently: 0) 
 Permanently: 0 
 1: Advertises that RTL8305SB has detected a remote fault. 
 0: No remote fault detected. 
 1: Advertises that RTL8305SB has flow control capability. 
 0: Without flow control capability. 
 Technology not supported. (Permanently =0) 
 1: 100Base-TX full duplex capable. 
 0: Not 100Base-TX full duplex capable. 
 1: 100Base-TX half duplex capable. 
 0: Not 100Base-TX half duplex capable. 
 1: 10Base-TX full duplex capable. 
 0: Not 10Base-TX full duplex capable. 
 1: 10Base-TX half duplex capable. 
 0: Not 10Base-TX half duplex capable. 
 [00001]=IEEE802.3 
 Mode 
 RO 
Default 
0 
 4.14 
 4.13 
 Acknowledge 
 Remote Fault 
 RO 
 RW 
0 
0 
 4.[12:11] 
 4.10 
 Reserved 
 Pause 
 RO 
 RW 
0 
 From pin 
 4.9 
 4.8 
 100Base-T4 
 100Base-TX-FD 
 RO 
 RW 
0 
From pin 
 4.7 
 100Base-TX 
 RW 
From pin 
 4.6 
 10Base-T-FD 
 RW 
From pin 
 4.5 
 10Base-T 
 RW 
1 
 4.[4:0] 
 Selector Field 
 RW 
00001