CC113L
SWRS108A
Page 6 of 68
4
Electrical Specifications
4.1
Current Consumption
TA = 25 C, VDD = 3.0 V if nothing else stated. All measurement results are obtained using [1] and [2]. Reduced current settings 5 for additional details on current consumption and sensitivity.
Parameter
Min
Typ
Max
Unit
Condition
Current consumption
in power down modes
0.2
1
A
Voltage regulator to digital part off, register values retained (SLEEP
state). All GDO pins programmed to 0x2F (HW to 0)
100
A
Voltage regulator to digital part off, register values retained, XOSC
165
A
Voltage regulator to digital part on, all other modules in power down
(XOFF state)
Current consumption
1.7
mA
Only voltage regulator to digital part and crystal oscillator running (IDLE
state)
8.4
mA
The current consumption for the intermediate states when going from
IDLE to RX, including the calibration state
Current consumption,
315 MHz
15.4
mA
Receive mode, 1.2 kBaud, reduced current, input at sensitivity limit
14.4
mA
Receive mode, 1.2 kBaud, register settings optimized for reduced
current, input well above sensitivity limit
15.2
mA
Receive mode, 38.4 kBaud, register settings optimized for reduced
current, input at sensitivity limit
14.3
mA
Receive mode, 38.4 kBaud, register settings optimized for reduced
current, input well above sensitivity limit
16.5
mA
Receive mode, 250 kBaud, register settings optimized for reduced
current, input at sensitivity limit
15.1
mA
Receive mode, 250 kBaud, register settings optimized for reduced
current, input well above sensitivity limit
Current consumption,
433 MHz
16.0
mA
Receive mode, 1.2 kBaud, register settings optimized for reduced
current, input at sensitivity limit
15.0
mA
Receive mode, 1.2 kBaud, register settings optimized for reduced
current, input well above sensitivity limit
15.7
mA
Receive mode, 38.4 kBaud, register settings optimized for reduced
current, input at sensitivity limit
15.0
mA
Receive mode, 38.4 kBaud, register settings optimized for reduced
current, input well above sensitivity limit
17.1
mA
Receive mode, 250 kBaud, register settings optimized for reduced
current, input at sensitivity limit
15.7
mA
Receive mode, 250 kBaud, register settings optimized for reduced
current, input well above sensitivity limit