XStream"燨EM燫F燤odule?燩roduct燤anual爒5.x00燵2006.02.24]?/DIV>
DR (DI3 Configuration) Command
AT Command: ATDR
Binary Command: 0x2D (45 decimal)
Parameter Range:   0 4
Parameter
Configuration
0
Disabled
1
DI3 I/O passing enabled
2
Connect on low
3
Disconnect on high
4
Connect and Disconnect
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: CD (DO3 Configuration),
CO (DO3 Timeout), MD (RF Mode)
Minimum Firmware Version Required: 4.30
<Serial Interfacing> DR Command is used to
configure DI3 (pin 2, SLEEP) for I/O line passing
(use with CD = 1 or 2 and CO) or controlling
connection status (use with MD = 1 or 2).
DT (Destination Address) Command
<Networking & Security> DT Command is used
to set the networking address of an XStream
Module. XStream Modules use three filtration
layers: Channels (ATHP), Vendor Identification
Number (ATID) and Destination Addresses
(ATDT). DT Command assigns an address to a
module that enables it to communicate only with
other modules having the same addresses. All
modules that share the same Destination Address can communicate freely with each other.
Modules in the same network with a different Destination Address (than that of the transmitter)
will listen to all transmissions to stay synchronized, but will not send any of the data out their
serial ports.
AT Command: ATDT
Binary Command: 0x00
Parameter Range:   0 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: HP (Hopping Channel), ID
(Module VID), MK (Address Mask)
E0 (Echo Off) Command
AT Command: ATE0
Binary Command: 0x0A (10 decimal)
<Command Mode Options> The E0 command
turns off character echo in AT Command Mode.
By default, echo is off.
E1 (Echo On) Command
AT Command: ATE1
Binary Command: 0x0B (11 decimal)
<Command Mode Options> E1 Command turns
on the echo in AT Command Mode. Each typed
character will be echoed back to the terminal
when ATE1 is active. E0 is the default.
ER (Receive Error Count) Command
<Diagnostics> Set/Read the receive error count.
The error-count records the number of packets
partially received then aborted on reception
error. This value returns to 0 after a reset and is
not non-volatile (value does not persist in the
modules memory after a power-up sequence).
Once the receive error count reaches its
maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count
value is explicitly changed or the module is reset.
AT Command: ATER
Binary Command: 0x0F (15 decimal)
Parameter Range:   0 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: GD (Receive Good Count)
牋牘?006燤axStream,營nc.燙onfidential燼nd燩roprietary?/DIV>
24?/DIV>
相關(guān)代理商/技術(shù)參數(shù) |
參數(shù)描述 |
XIB-R |
功能描述:界面模塊 RS-232/485 interface 24XStream 9XCite
RoHS:否 制造商:4D Systems 產(chǎn)品:Serial Converters 通道/端口數(shù)量: 數(shù)據(jù)速率: 接口類型:USB, UART 工作電源電壓:3.3 V, 5 V 最大工作溫度: |
XIB-U |
功能描述:界面模塊 USB interface board 24XStream 9XCite
RoHS:否 制造商:4D Systems 產(chǎn)品:Serial Converters 通道/端口數(shù)量: 數(shù)據(jù)速率: 接口類型:USB, UART 工作電源電壓:3.3 V, 5 V 最大工作溫度: |
XIC25040 |
制造商:XIC 功能描述:25040 24HR '6 |
XILINXPWR-079 |
功能描述:電源管理IC開發(fā)工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 類型:Battery Management 工具用于評估:MAX17710GB 輸入電壓: 輸出電壓:1.8 V |
XILINXPWR-080 |
功能描述:電源管理IC開發(fā)工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 類型:Battery Management 工具用于評估:MAX17710GB 輸入電壓: 輸出電壓:1.8 V |