142
LRDII:
The line remote defect indication interrupt status (LRDII) bit is an event indicator. LRDII is set
to logic 1 to indicate any change in the status of LRDIV. The interrupt status bit is
independent of the interrupt enable bit. LRDII is cleared to logic 0 when this register is read.
APSBFI:
The APS byte failure interrupt status (APSBFI) bit is an event indicator. APSBFI is set to logic
1 to indicate any change in the status of APSBFV. The interrupt status bit is independent of
the interrupt enable bit. APSBFI is cleared to logic 0 when this register is read.
COAPSI:
The change of APS bytes interrupt status (COAPSI) bit is an event indicator. COAPSI is set
to logic 1 to indicate a new APS bytes. The interrupt status bit is independent of the interrupt
enable bit. COAPSI is cleared to logic 0 when this register is read.
COSSMI:
The change of SSM message interrupt status (COSSMI) bit is an event indicator. COSSMI is
set to logic 1 to indicate a new SSM message. The interrupt status bit is independent of the
interrupt enable bit. COSSMI is cleared to logic 0 when this register is read.
SBIPEI:
The section BIP error interrupt status (SBIPEI) bit is an event indicator. SBIPEI is set to logic
1 to indicate a section BIP error. The interrupt status bit is independent of the interrupt
enable bit. SBIPEI is cleared to logic 0 when this register is read.
LBIPEI:
The line BIP error interrupt status (LBIPEI) bit is an event indicator. LBIPEI is set to logic 1 to
indicate a line BIP error. The interrupt status bit is independent of the interrupt enable bit.
LBIPEI is cleared to logic 0 when this register is read.
LREIEI:
The line REI error interrupt status (LREIEI) bit is an event indicator. LREIEI is set to logic 1 to
indicate a line REI error. The interrupt status bit is independent of the interrupt enable bit.
LREIEI is cleared to logic 0 when this register is read.