參數(shù)資料
型號(hào): DS33Z11
廠商: MAXIM INTEGRATED PRODUCTS INC
元件分類: 網(wǎng)絡(luò)接口
英文描述: Ethernet Mapper
中文描述: DATACOM, NETWORK INTERFACE SUPPORT CIRCUIT, PBGA169
封裝: 14 X 14 MM, 1 MM PITCH, CSBGA-169
文件頁數(shù): 118/169頁
文件大小: 1049K
代理商: DS33Z11
DS33Z11 Ethernet Mapper
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
118 of 169
SU.RFSB0
Receive Frame Status Byte 0
154h
7
6
5
4
3
2
1
0
FL7
0
FL6
0
FL5
0
FL4
0
FL3
0
FL2
0
FL1
0
FL0
0
Bits 0 - 7: Frame Length (FL[0:7])
These 8 bits are the low byte of the length (in bytes) of the received frame,
with FCS and Padding. If Automatic Pad Stripping is enabled, this value is the length of the received packet
without PCS or Pad bytes. The upper 6 bits are contained in SU.RFSB1.
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
SU.RFSB1
Receive Frame Status Byte 1
155h
7
RF
0
6
5
4
3
2
1
0
WT
0
FL13
0
FL12
0
FL11
0
FL10
0
FL9
0
FL8
0
Bit 7: Runt Frame (RF)
This bit is set to 1 if the received frame was altered by a collision or terminated within the
collision window.
Bit 6: Watchdog Timeout (WT)
This bit is set to 1 if a packet receive time exceeds 2048 byte times. After 2048
byte times the receiver is disabled and the received frame will fail CRC check.
Bits 0-5: Frame Length (FL[8:13])
These 6 bits are the upper bits of the length (in bytes) of the received frame,
with FCS and Padding. If Automatic Pad Stripping is enabled, this value is the length of the received packet
without PCS or Pad bytes.
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
SU.RFSB2
Receive Frame Status Byte 2
156h
7
-
0
6
-
0
5
4
3
2
FT
0
1
0
CRCE
0
DB
0
MIIE
0
CS
0
FTL
0
Bit 5: CRC Error (CRCE)
This bit is set to 1 if the received frame does not contain a valid CRC value.
Bit 4: Dribbling Bit (DB)
This bit is set to 1 if the received frame contains a non-integer multiple of 8 bits. It does
not indicate that the frame is invalid. This bit is not valid for runt or collided frames.
Bit 3: MII Error (MIIE)
This bit is set to 1 if an error was found on the MII bus.
Bit 2: Frame Type (FT)
This bit is set to 1 if the received frame exceeds 1536 bytes. It is equal to zero if the
received frame is an 802.3 frame. This bit is not valid for runt frames.
Bit 1: Collision Seen (CS)
This bit is set to 1 if a late collision occurred on the received packet. A late collision is
one that occurs after the 64-byte collision window.
Bit 0: Frame Too Long (FTL)
This bit is set to 1 if a frame exceeds the 1518 byte maximum standard Ethernet
frame. This bit is only an indication, and causes no frame truncation.
相關(guān)PDF資料
PDF描述
DS33ZH11 Ethernet Mapper
DS3803 1024K Flexible NV SRAM SIMM(1024K靈活的非易失性SRAM SIMM)
DS3903E-020 Triple 128-Position Nonvolatile Digital Potentiometer
DS3994 4-Channel Cold-Cathode Fluorescent Lamp Controller
DS4077 77.76MHz VCXO
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
DS33Z11+ 功能描述:網(wǎng)絡(luò)控制器與處理器 IC Ethernet Mapper RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
DS33Z11+UNUSED 功能描述:網(wǎng)絡(luò)控制器與處理器 IC Ethernet Mapper RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
DS33Z11DK 功能描述:以太網(wǎng)開發(fā)工具 DS33Z11 Dev Kit RoHS:否 制造商:Micrel 產(chǎn)品:Evaluation Boards 類型:Ethernet Transceivers 工具用于評估:KSZ8873RLL 接口類型:RMII 工作電源電壓:
DS33Z41 功能描述:網(wǎng)絡(luò)控制器與處理器 IC Quad IMUX Ethernet Mapper RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
DS33Z41DK 功能描述:以太網(wǎng)開發(fā)工具 DS33Z41 Dev Kit RoHS:否 制造商:Micrel 產(chǎn)品:Evaluation Boards 類型:Ethernet Transceivers 工具用于評估:KSZ8873RLL 接口類型:RMII 工作電源電壓: