A-6
Mindspeed Technologies
28229-DSH-001-B
IMA Version 1.1 PICS Proforma
CX28224/5/9 Data Sheet
BIP.55
Does the implementation only change the value M at group
start-up time?
M
(R-43)
Yes X No__
BIP.56
Does the implementation use on transmit the value configured by
the UM?
(O-2)
M
(CR-1)
Yes X No__
BIP.57
Does the implementation allow different values of M in both Tx and
Rx directions?
(O-2)
M
(CR-2)
Yes X No__
BIP.58
Does the implementation synchronize its incoming links using the
received M value for IMA frame synchronization?
(O-2)
M
(CR-3)
Yes X No__
BIP.59
Does the implementation abort the start-up procedure using the
corresponding code in the Group Status and Control field of the
ICP cell when it does not support the received M?
M
(R-44)
Yes X No__
BIP.60
Does the implementation allow to configure the value M?
O
(O-3)
Yes X No__
BIP.61
Does the implementation set the SCCI field to the previously
transmitted SCCI field value, incremented modulo 256, to indicate
a change on at least one of the fields appearing in octets 12
through 49 in the transmitted ICP cell?
M
(R-45)
Yes X No__
BIP.62
Does the implementation use the SCCI field to identify received ICP
cells for processing when ICP cells are monitored on more than
one link, or when the monitored link has changed?
M
(R-46)
Yes X No__
BIP.63
Does the implementation process the fields in octets 12 through
49 if the SCCI field has advanced beyond the SCCI value of the last
processed ICP cell?
M
(R-46)
Yes X No__
BIP.64
Does the implementation select the IMA ID at group start-up time?
M
(R-47)
Yes X No__
BIP.65
Does the implementation transmit the IMA ID in the IMA ID field?
M
(R-48)
Yes X No__
BIP.66
Does the implementation allow to configure the value of IMA ID?
O
(O-4)
Yes X No__
BIP.67
Does the implementation use the "Group Symmetry Mode" field,
specified in Table 2 on page 31, to indicate the symmetry of the
IMA group?
M
(R-49)
Yes X No__
BIP.68
Does the implementation ensure that the symmetry of the group is
only established or changed at group start-up time?
M
(R-50)
Yes X No__
BIP.69
Does the implementation support the Symmetrical Configuration
and Operation mode?
M
(R-51)
Yes X No__
BIP.70
Does the implementation support the Symmetrical Configuration
and Asymmetrical Operation mode?
O
(O-5)
Yes X No__
BIP.71
Does the implementation support the Asymmetrical Configuration
and Operation mode?
O
(O-6)
Yes X No__
BIP.72
Does the implementation abort the start-up procedure using the
appropriate code defined in the “Group Status and Control” field of
the ICP cell (as specified in Table 2 on page 31) if the NE does not
support the symmetry mode proposed by the FE?
M
(R-52)
Yes X No__
Table A-1. Basic IMA Protocol (BIP) Definition Functions (4 of 5)
Item
Protocol feature
Cond. for
Status
Pred.
Ref.
Support