Data Sheet
73
Zarlink Semiconductor Inc.
PVMAP20_0,1,2,3
I
2
C Address h4C,67,82,9D; CPU Address:h152, 153, 154, 155)
PVMAP21_0,1,2,3
I
2
C Address h4D,68,83,9E; CPU Address:h156, 157, 158, 159)
PVMAP22_0,1,2,3
I
2
C Address h4E,69,84,9F; CPU Address:h15A, 15B, 15C, 15D)
PVMAP23_0,1,2,3
I
2
C Address h4F,6A,85,A0; CPU Address:h15E, 15F, 160, 161)
PVMAP24_0,1,2,3
I
2
C Address h50,6B,86,A1; CPU Address:h162, 163, 164, 165) (CPU port)
PVMAP25_0,1,2,3
I
2
C Address h51,6C,87,A2; CPU Address:h166, 167, 168, 169) (Giagabit port 1)
PVMAP26_0,1,2,3
I
2
C Address h52,6D,88,A3; CPU Address:h16A, 16B, 16C, 16D) (Gigabit port 2)
14.6.1 PVMODE
I
2
C Address: h0A4, CPU Address:h170
Accessed by CPU, serial interface (R/W)
7
6
5
4
3
2
1
0
MAC05
MMA
STP
SM0
rPCS
DF
SL
Vmod
Bit [0]:
VLAN Mode (Default = 0)
1 Tag based VLAN Mode
0 Port based VLAN Mode
Bit [1]:
Slow learning (Default = 0)
Same function as SE_OP MODE bit 7. Either bit can enable the function;
both need to be turned off to disable the feature.
Bit [2]:
Disable dropping of frames with destination MAC addresses
0180C2000001 to 0180C200000F (Default = 0)
0: Drop all frames in this range
1: Disable dropping of frames in this range
Bit [3]:
Disable Reset PCS (Default = 0)
0: Enable reset PCS. PCS FIFO will be reset when received a PCS symbol error.
1: Disable reset PCS
Bit [4]:
Support MAC address 0 (Default = 0)
0: MAC address 0 is not learned.
1: MAC address 0 is learned.
Bit [5]:
Disable IEEE multicast control frame (0180C2000000 to 0180C20000FF)
to CPU in managed mode (Default = 0)
0: Packet is forwarded to CPU
1: Packet is forwarded as multicast
Bit [6]:
Multiple MAC addresses (Default = 0)
0: Single MAC address is assigned to CPU. Registers MAC0 to MAC5 are used
to program the CPU MAC address.
1: One block of 32 MAC addresses are assigned to CPU. The block is defined in
an increase way from the MAC address programmed in registers MAC0 to
MAC5.
相關(guān)PDF資料
PDF描述
MVTX2604AG Managed 24-Port 10/100 Mb + 2 Port 1 Gb Ethernet Switch
MVTX2801 Unmanaged 4-Port 1000 Mbps Ethernet Switch
MVTX2801AG Unmanaged 4-Port 1000 Mbps Ethernet Switch
MVTX2802 Managed 4-Port 1000 Mbps Ethernet Switch
MVTX2802AG Managed 4-Port 1000 Mbps Ethernet Switch
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
MVTX2604A 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MVTX260x Physical Port Control
MVTX2604AG 制造商:ZARLINK 制造商全稱:Zarlink Semiconductor Inc 功能描述:Managed 24-Port 10/100 Mb + 2 Port 1 Gb Ethernet Switch
MVTX2801 制造商:ZARLINK 制造商全稱:Zarlink Semiconductor Inc 功能描述:Unmanaged 4-Port 1000 Mbps Ethernet Switch
MVTX2801A 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Unmanaged 4 port Gigabit Ethernet switch
MVTX2801AG 制造商:ZARLINK 制造商全稱:Zarlink Semiconductor Inc 功能描述:Unmanaged 4-Port 1000 Mbps Ethernet Switch