488
SAM9G45 [DATASHEET]
6438K–ATARM–12-Feb-13
31.10 Slave Mode
31.10.1
Definition
The Slave Mode is defined as a mode where the device receives the clock and the address from another device
called the master.
In this mode, the device never initiates and never completes the transmission (START, REPEATED_START and
STOP conditions are always provided by the master).
31.10.2
Application Block Diagram
Figure 31-24. Slave Mode Typical Application Block Diagram
31.10.3
Programming Slave Mode
The following fields must be programmed before entering Slave mode:
1.
SADR (TWI_SMR): The slave device address is used in order to be accessed by master devices in read
or write mode.
2.
MSDIS (TWI_CR): Disable the master mode.
3.
SVEN (TWI_CR): Enable the slave mode.
As the device receives the clock, values written in TWI_CWGR are not taken into account.
31.10.4
Receiving Data
After a Start or Repeated Start condition is detected and if the address sent by the Master matches with the Slave
address programmed in the SADR (Slave ADdress) field, SVACC (Slave ACCess) flag is set and SVREAD (Slave
READ) indicates the direction of the transfer.
SVACC remains high until a STOP condition or a repeated START is detected. When such a condition is detected,
EOSACC (End Of Slave ACCess) flag is set.
31.10.4.1
Read Sequence
In the case of a Read sequence (SVREAD is high), TWI transfers data written in the TWI_THR (TWI Transmit
Note that at the end of the read sequence TXCOMP (Transmission Complete) flag is set and SVACC reset.
As soon as data is written in the TWI_THR, TXRDY (Transmit Holding Register Ready) flag is reset, and it is set
when the shift register is empty and the sent data acknowledged or not. If the data is not acknowledged, the NACK
flag is set.
Note that a STOP or a repeated START always follows a NACK.
Host with
TWI
Interface
TWD
TWCK
LCD Controller
Slave 1
Slave 2
Slave 3
RR
VDD
Host with TWI
Interface
Host with TWI
Interface
Master