Data Sheets
Alternistor Triacs
2002 Teccor Electronics
Thyristor Product Catalog
E4 - 7
http://www.teccor.com
+1 972-580-7777
Figure E4.1 Maximum Allowable Case Temperature versus
On-state Current (6 A to 12 A)
Figure E4.2 Maximum Allowable Case Temperature versus
On-state Current (8 A to 12 A)
Figure E4.3 Maximum Allowable Case Temperature versus
On-state Current (16 A)
Figure E4.4 Maximum Allowable Case Temperature versus
On-state Current (25 A to 40 A)
Figure E4.5 On-state Current versus On-state Voltage (Typical)
(6 A to 12 A)
Figure E4.6 On-state Current versus On-state Voltage (Typical)
(16 A to 40 A)
0
2
4
6
8
10
12
14
0
60
70
80
90
100
110
120
130
RMS On-State Current [l
T(RMS)
] - AMPS
M
C
)
C
12A TO-220 (ISOLATED)
10A TO-220 (NON-ISOLATED)
AND D
PAK
6A TO-220 (ISOLATED)
6A TO-220
(NON-ISOLATED)
AND D
PAK
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
CASE TEMPERATURE: Measured as
shown on Dimensional Drawing
0
2
4
6
8
10
12
14
0
60
70
80
90
100
110
120
130
RMS On-state Current [l
T(RMS)
] – Amps
M
T
C
)
12 A TO-220 (Non-isolated)
and TO-263
10 A TO-220 (Isolated)
8 A TO-220 (Non-isolated),
TO-263, TO-251, and TO-252
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
CASE TEMPERATURE: Measured as
shown on Dimensional Drawing
8 A TO-220 (Isolated)
0
60
70
80
90
100
110
120
130
0
5
10
15
RMS On-state Current [I
T(RMS)
] – Amps
M
C
C
)
16A TO-220 (Non-isolated) and TO-263
16A TO-220 (Isolated)
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
shown on Dimensional Drawing
0
10
20
30
40
50
50
60
70
80
90
100
110
120
130
RMS On-state Current [l
T(RMS)
] – Amps
M
C
)
35 A TO-220 (Non-isolated)
and TO-263
25 A and 30 A
TO-220 (Isolated)
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
CASE TEMPERATURE: Measured as
shown on Dimensional Drawing
40 A TO-218
(Isolated)
25
25 A TO-220 (Non-isolated)
TO-218 (Isolated)
TO-263
0
2
6
8
10
12
14
16
18
20
0
0.6
0.8
1.0
1.2
1.4
1.6
Positive or Negative Instantaneous
On-state Voltage (v
T
) – Volts
P
T
)
T
C
= 25 C
4
6 A to 12 A Devices
90
80
70
60
50
40
30
20
10
0
0
0.6
0.8
1.0
1.2
1.4
1.6
P
O
T
)
T
C
= 25C
1.8
Positive or Negative Instantaneous On-state Voltage (v
T
) – Volts
40 A Devices
16 A Devices
25 A to 35 A Devices