Electrical Specification Notes
(1)
For either polarity of MT2 with reference to MT1 terminal
(2)
For either polarity of gate voltage V
GT
with reference to MT1
terminal
See Gate Characteristics and Definition of Quadrants.
See Figure E1.4 for i
T
versus v
T
.
See Figure E1.6 for V
GT
versus T
C
.
See Figure E1.7 for I
GT
versus T
C
.
See Figure E1.5 for I
H
versus T
C
.
See Figure E1.9 for surge rating and specific duration.
See Figure E1.8 for t
gt
versus I
GT
.
(10) See Figure E1.2 and Figure E1.3 for maximum allowable case
temperature at maximum rated current.
(11) See Figure E1.1, Figure E1.2, and Figure E1.3 for T
A
or T
C
versus
I
T(RMS)
.
(12) See package outlines for lead form configurations. When ordering
special lead forming, add type number as suffix to part number.
(13) Pulse width
≤
10 μs
(14) T
C
or T
L
= T
J
for test conditions in off state
(15) Minimum non-trigger V
GT
at 110 °C is 0.2 V.
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Gate Characteristics
Teccor triacs may be turned on between gate and MT1 terminals
in the following ways:
In-phase signals (with standard AC line) using Quadrants I
and III
Application of unipolar pulses (gate always positive or nega-
tive), using Quadrants II and III with negative gate pulses and
Quadrants I and IV with positive gate pulses
When maximum surge capability is required, pulses should be a
minimum of one magnitude above I
GT
rating with a steep rising
waveform (
≤
1 μs rise time).
Definition of Quadrants
V
TM
(1) (4)
V
GT
I
H
I
GTM
(13)
P
GM
(13)
P
G(AV)
I
TSM
(8) (10)
dv/dt(c)
(1) (10)
dv/dt
(1)
t
gt
(9)
I
2
t
di/dt
Volts
(2) (5) (15)
Volts
(1) (7)
mAmps
Amps
Watts
Watts
Amps
60/50 Hz
Volts/μSec
Volts/μSec
T
C
= 100 °C
TYP
40
30
20
40
30
20
45
40
30
40
30
20
45
40
30
μSec
Amps
2
Sec
Amps/μSec
T
C
= 25 °C
MAX
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
T
C
= 25 °C
MAX
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
MAX
10
10
10
10
10
10
20
20
20
10
10
10
20
20
20
TYP
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
TYP
3
3
3
3
3
3
3.2
3.2
3.2
3
3
3
3.2
3.2
3.2
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
60/50
60/50
60/50
60/50
60/50
60/50
60/50
60/50
60/50
80/65
80/65
80/65
80/65
80/65
80/65
15
15
15
15
15
15
15
15
15
26.5
26.5
26.5
26.5
26.5
26.5
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
MT2 POSITIVE
(Positive Half Cycle)
MT2 NEGATIVE
(Negative Half Cycle)
MT1
MT2
+
I
GT
REF
QII
QIII
MT1
I
GATE
MT2
REF
MT1
MT2
REF
MT1
MT2
REF
QI
QIV
ALL POLARITIES ARE REFERENCED TO MT1
(
-
)
I
GATE
(+)
I
GT
-
I
GATE
(
-
)
I
GATE
(+)