5.3.1. Starting a Conversion
A conversion can be initiated in one of four ways, depending on the programmed states of the ADC0 Start
of Conversion Mode bits (AD0CM1-0) in register ADC0CN. Conversions may be initiated by one of the fol-
lowing:
Writing a ‘1’ to the AD0BUSY bit of register ADC0CN
A Timer 3 overflow (i.e., timed continuous conversions)
A rising edge on the CNVSTR input signal (pin P0.6)
A Timer 2 overflow (i.e., timed continuous conversions)
Writing a ‘1’ to AD0BUSY provides software control of ADC0 whereby conversions are performed "on-
demand.” During conversion, the AD0BUSY bit is set to logic 1 and reset to logic 0 when the conversion is
complete. The falling edge of AD0BUSY triggers an interrupt (when enabled) and sets the ADC0 interrupt
flag (AD0INT). Note: When polling for ADC conversion completions, the ADC0 interrupt flag (AD0INT)
should be used. Converted data is available in the ADC0 data registers, ADC0H:ADC0L, when bit AD0INT
is logic 1. Note that when Timer 2 or Timer 3 overflows are used as the conversion source, Low Byte over-
flows are used if Timer 2/3 is in 8-bit mode; High byte overflows are used if Timer 2/3 is in 16-bit mode. See
Important Note About Using CNVSTR: The CNVSTR input pin also functions as Port Pin P0.6. When the
CNVSTR input is used as the ADC0 conversion source, Port Pin P0.6 should be skipped by the Digital
Crossbar. To configure the Crossbar to skip P0.6, set bit 6 in the P0SKIP register to logic 1. See
5.3.2. Tracking Modes
According to
Table 5.3 and
Table 5.4, each ADC0 conversion must be preceded by a minimum tracking
time for the converted result to be accurate. ADC0 has three tracking modes: Pre-Tracking, Post-Tracking,
and Dual-Tracking. Pre-Tracking Mode provides the minimum delay between the convert start signal and
end of conversion by tracking continuously before the convert start signal. This mode requires software
management in order to meet minimum tracking requirements. In Post-Tracking Mode, a programmable
tracking time starts after the convert start signal and is managed by hardware. Dual-Tracking Mode maxi-
mizes tracking time by tracking before and after the convert start signal.
Figure 5.3 shows examples of the
three tracking modes.
Pre-Tracking Mode is selected when AD0TM is set to 10b. Conversions are started immediately following
the convert start signal. ADC0 is tracking continuously when not performing a conversion. Software must
allow at least the minimum tracking time between each end of conversion and the next convert start signal.
The minimum tracking time must also be met prior to the first convert start signal after ADC0 is enabled.
Post-Tracking Mode is selected when AD0TM is set to 01b. A programmable tracking time based on
AD0TK is started immediately following the convert start signal. Conversions are started after the pro-
grammed tracking time ends. After a conversion is complete, ADC0 does not track the input. Rather, the
sampling capacitor remains disconnected from the input making the input pin high-impedance until the
next convert start signal.
Dual-Tracking Mode is selected when AD0TM is set to 11b. A programmable tracking time based on
AD0TK is started immediately following the convert start signal. Conversions are started after the pro-
grammed tracking time ends. After a conversion is complete, ADC0 tracks continuously until the next con-
version is started.