第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)當(dāng)前第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)
88
EPSON
S1C63653 TECHNICAL MANUAL
CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (R/f Converter)
4.12.3 Operation of R/f conversion
Counter
The R/f converter incorporates two types of counters: measurement counter MCxx and time base
counter TCxx. The measurement counter is a 20-bit up counter that counts the CR oscillation clock
with the reference resistance or sensor selected by software. The time base counter is a 20-bit up/
down counter to equal both oscillation times for the reference resistance and the sensor. The time base
counter uses the count clock selected by the RFCLK register (OSC1 or OSC3). Each counter permits
reading and writing on a 4-bit basis.
First start an R/f conversion for the reference resistance. The measurement counter starts counting up
and the time base counter starts counting down. The counters stop counting when the measurement
counter overflows (counter = 00000H). By resetting the time base counter to 00000H before starting an
R/f conversion for the reference resistance, the reference oscillation time will be obtained from the
time base counter.
Then start an R/f conversion for the sensor, the measurement counter starts counting up from 00000H
and the time base counter starts counting up from the counted value. The counters stop counting
when the time base counter overflows (counter = 00000H). The oscillation time in this phase is the
same as that of the reference resistance.
Therefore, by converting a proper initial value for counting of the oscillation of the reference resis-
tance into a complement (value subtracted from 00000H) and setting it into the measurement counter
before starting to count, the number of counts for the sensor oscillation is obtained by reading the
measurement counter after the R/f conversion. In other words, the difference between the reference
resistance and sensor oscillation frequencies can be found easily. For instance, if resistance values of
the reference resistance and the sensor are equivalent, the same value as the initial value before
converting into a complement will be obtained as the result.
The time base counter allows reading of the counter value and presetting of data. By saving the
counter value after the reference oscillation has completed into the RAM, the subsequent reference
oscillation phase can be omitted. The sensor oscillation can be started after setting the saved value to
the time base counter and 00000H to the measurement counter.
Note: When setting the measurement counter, always write 5 words of data continuously in order from
the lower address (FF92H
→ FF93H → FF94H → FF95H → FF96H). Furthermore, an LD instruc-
tion should be used for writing data to the measurement counter and a read-modify-write instruc-
tion (AND, OR, ADD, SUB, etc.) cannot be used.
R/f conversion sequence
An R/f conversion for the reference resistance starts by writing "1" to the register RFRUNR.
However, an initial value must be set to the measurement counter and the time base counter must be
cleared to 00000H before starting the R/f conversion.
When R/f conversion is initiated by the RFRUNR register, oscillation by the reference resistance
begins, and the measurement counter starts counting up from the initial value by the oscillation clock.
The time base counter also starts counting down by the OSC1 clock.
If the measurement counter becomes 00000H due to overflow, the oscillation is terminated. At the
same time an interrupt occurs and the RFRUNR register is set to "0", and the R/f converter circuit
stops operation completely.
The time base counter value should be saved into the RAM for R/f conversion of the sensor.
Figure 4.12.3.1 shows a timing chart for the reference oscillation.
相關(guān)PDF資料
PDF描述
S1C6F567D0A0100 MICROCONTROLLER, UUC141
S1C6N3B0D0A0100 MICROCONTROLLER, UUC54
S1C6P366D0A0100 4-BIT, FLASH, 4.1 MHz, MICROCONTROLLER, UUC102
S1C6P466D0A0A00 MICROCONTROLLER, UUC140
S1C6S2L7D 4-BIT, MROM, 0.032 MHz, MICROCONTROLLER, UUC58
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
S1C63656 制造商:EPSON 制造商全稱(chēng):EPSON 功能描述:4-bit Single Chip Microcomputer
S1C63657 制造商:EPSON 制造商全稱(chēng):EPSON 功能描述:CMOS 4-bit Single Chip Microcontroller
S1C63658 制造商:EPSON 制造商全稱(chēng):EPSON 功能描述:4-bit Single Chip Microcomputer
S1C63666 制造商:EPSON 制造商全稱(chēng):EPSON 功能描述:4-bit Single Chip Microcomputer
S1C63709 制造商:EPSON 制造商全稱(chēng):EPSON 功能描述:4-bit Single Chip Microcomputer