413
SAM4CM Series [DATASHEET]
Atmel-11203C-ATARM-SAM4CM32-SAM4CM16-SAM4CM8-Datasheet_06-Oct-14
20.6.8 Supply Controller Status Register
Name:
SUPC_SR
Address:
0x400E1424
Access:
Read-only
Note: Because of the asynchronism between the Slow Clock (SCLK) and the System Clock (MCK), the status register flag reset is taken
into account only two slow clock cycles after the read of the SUPC_SR.
FWUPS: FWUP Wake-up Status (cleared on read)
0 (NO): No wake-up due to the assertion of the FWUP pin has occurred since the last read of SUPC_SR.
1 (PRESENT): At least one wake-up due to the assertion of the FWUP pin has occurred since the last read of SUPC_SR.
WKUPS: WKUP Wake-up Status (cleared on read)
0 (NO): No wake-up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.
1 (PRESENT): At least one wake-up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.
SMWS: Supply Monitor Detection Wake-up Status (cleared on read)
0 (NO): No wake-up due to a supply monitor detection has occurred since the last read of SUPC_SR.
1 (PRESENT): At least one wake-up due to a supply monitor detection has occurred since the last read of SUPC_SR.
BODRSTS: Brownout Detector Reset Status (cleared on read)
0 (NO): No core brownout rising edge event has been detected since the last read of SUPC_SR.
1 (PRESENT): At least one brownout output rising edge event has been detected since the last read of SUPC_SR.
When the voltage remains below the defined threshold, there is no rising edge event at the output of the brownout detec-
tion cell. The rising edge event occurs only when there is a voltage transition below the threshold.
SMRSTS: Supply Monitor Reset Status (cleared on read)
0 (NO): No supply monitor detection has generated a system reset since the last read of SUPC_SR.
1 (PRESENT): At least one supply monitor detection has generated a system reset since the last read of SUPC_SR.
SMS: Supply Monitor Status (cleared on read)
0 (NO): No supply monitor detection since the last read of SUPC_SR.
1 (PRESENT): At least one supply monitor detection since the last read of SUPC_SR.
SMOS: Supply Monitor Output Status
31
–
30
–
29
–
28
27
26
25
24
WKUPIS12
WKUPIS11
WKUPIS10
WKUPIS9
WKUPIS8
23
22
21
20
19
18
17
16
WKUPIS7
WKUPIS6
WKUPIS5
WKUPIS4
WKUPIS3
WKUPIS2
WKUPIS1
WKUPIS0
15
14
13
12
11
–
10
–
9
–
8
BUPPORS
LPDBCS1
LPDBCS0
FWUPIS
LCDS
7
6
5
4
3
2
1
0
OSCSEL
SMOS
SMS
SMRSTS
BODRSTS
SMWS
WKUPS
FWUPS