SIDACtor
Data Book and Design Guide
TeleLink
Fuse
The
TeleLink
Surface Mount (SM) surge resistant fuse offers circuit protection without
requiring a series resistor. When used in conjunction with the
SIDACtor
Transient Voltage
Suppressor (TVS), the
TeleLink
SM fuse and the
SIDACtor
TVS provide a complete
regulatory-compliant solution for standards such as GR 1089, TIA-968 (formerly known as
FCC Part 68), UL 60950, and ITU K.20 and K.21. No series resistor is required for the
F1250T and F1251T to comply with these standards.
Contact factory for enhanced K.20 and K.21 details.
* Interrupt test characterized at 50° to 70° phase angle. Phase angles approximating 90° may result in damage to the body of the fuse.
Notes:
The
TeleLink
SM fuse is designed to carry 100% of its rated current for four hours and 250% of its rated current for one second
minimum and 120 seconds maximum. Typical time is four to 10 seconds. For optimal performance, an operating current of 80% or
less is recommended.
I
2
t is a non-repetitive RMS surge current rating for a period of 16.7 ms.
Notes:
Typical inductance 4 μH up to 500 MHz.
Resistance changes 0.5% for every °C.
Resistance is measured at 10% rated current.
Surge Ratings
TeleLink
SM Fuse
I
2x10 μs
Amps
I
10x160 μs
Amps
I
10x560 μs
Amps
I
10x1000 μs
Amps
F0500T
not rated
75
45
35
F1250T
500
160
115
100
F1251T
500
160
115
100
Interrupting Values
TeleLink
SM
Fuse
Voltage
Rating
Current
Rating
I
2
t Measured
at DC Rated
Voltage
1.3 A
2
s
22.2 A
2
s
30 A
2
s
Interrupting Rating
Voltage, Current
MIN
TYP
MAX
F0500T
250 V
500 mA
600 V, 40 A
1 ms
2 ms
60 ms
F1250T
250 V
1.25 A
600 V, 60 A *
1 ms
2 ms
60 ms
F1251T
250 V
2 A
600 V, 60 A *
1 ms
2 ms
60 ms
Resistance Ratings
TeleLink
SM Fuse
Typical Voltage Drop
@ Rated Current
DC Cold Resistance
MIN
MAX
F0500T
0.471 V
0.420
0.640
F1250T
0.205 V
0.107
0.150
F1251T
0.110 V
0.050
0.100