SIDACtor Device
http://www.teccor.com
+1 972-580-7777
2 - 26
2002 Teccor Electronics
SIDACtor
Data Book and Design Guide
SIDACtor
Device
The modified TO-220 Type 61
SIDACtor
solid state protection device can be used in
telecommunication protection applications that do not reference earth ground.
SIDACtor
devices are used to enable equipment to meet various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968 (formerly
known as FCC Part 68).
* For surge ratings, see table below.
General Notes:
All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
Listed
SIDACtor
devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
V
DRM
is measured at I
DRM.
V
S
is measured at 100 V/μs.
Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
Off-state capacitance is measured at 1 MHz with a 2 V bias and is a typical value.
Electrical Parameters
Part
Number *
V
Volts
V
Volts
V
Volts
I
μAmps
I
mAmps
I
Amps
I
mAmps
C
O
pF
P2000AA61
180
220
4
5
800
2.2
150
30
P2200AA61
200
240
4
5
800
2.2
150
30
P2400AA61
220
260
4
5
800
2.2
150
30
P2500AA61
240
290
4
5
800
2.2
150
30
P3000AA61
270
330
4
5
800
2.2
150
30
P3300AA61
300
360
4
5
800
2.2
150
30
Surge Ratings
Series
I
0.2x310 μs
Amps
I
2x10 μs
Amps
I
8x20 μs
Amps
I
10x160 μs
Amps
I
10x560 μs
Amps
I
5x320 μs
Amps
I
10x1000 μs
Amps
I
60 Hz
Amps
di/dt
Amps/μs
A
20
150
150
90
50
75
45
20
500