Twin SLIC Protector
http://www.teccor.com
+1 972-580-7777
2 - 48
2002 Teccor Electronics
SIDACtor
Data Book and Design Guide
Twin SLIC Protector
Subscriber Line Interface Circuits (SLIC) are highly susceptible to transient voltages, such
as lightning and power cross conditions. To minimize this threat, Teccor provides this dual-
chip, fixed-voltage SLIC protector device.
For specific design criteria, see details in Figure 3.23.
* For surge ratings, see table below.
General Notes:
All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
V
DRM
is measured at I
DRM.
V
S
and V
F
are measured at 100 V/μs.
Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
Off-state capacitance is measured across pins 1-2 or 2-3 at 1 MHz with a 2 V bias. Capacitance across pins 1-3 is approximately
half.
Parallel capacitive loads may affect electrical parameters.
Compliance with GR 1089 or UL 60950 power cross tests may require special design considerations. Contact the factory for further
information.
Electrical Parameters
Part
Number *
V
DRM
Volts
V
S
Volts
V
DRM
Volts
V
S
Volts
V
Volts
V
Volts
I
μAmps
I
mAmps
I
Amps
I
mAmps
C
O
pF
Pins 1-2, 2-3
Pins 1-3
P0641CA2
58
77
58
77
4
5
5
800
1
120
60
P0721CA2
65
88
65
88
4
5
5
800
1
120
60
P0901CA2
75
98
75
98
4
5
5
800
1
120
60
P1101CA2
95
130
95
130
4
5
5
800
1
120
60
Surge Ratings (Preliminary Data)
Series
I
PP
2x10 μs
Amps
I
PP
8x20 μs
Amps
I
PP
10x160 μs
Amps
I
PP
10x560 μs
Amps
I
PP
10x1000 μs
Amps
I
TSM
60 Hz
Amps
di/dt
Amps/μs
A
150
150
90
50
45
20
500
1
3
2
(T)
(G)
(R)