Ethernet/10BaseT/100BaseT Protector
http://www.teccor.com
+1 972-580-7777
2 - 14
2002 Teccor Electronics
SIDACtor
Data Book and Design Guide
Ethernet/10BaseT/100BaseT Protector
The DO-214AA
SIDACtor
Ethernet protection series is intended for applications sensitive to
load values. Typically, high speed connections require a lower capacitance. C
O
values are
40% lower than standard devices.
SIDACtor
devices are used to enable equipment to meet various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968 (formerly
known as FCC Part 68).
* For surge ratings, see table below.
General Notes:
All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
Listed
SIDACtor
devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
V
DRM
is measured at I
DRM.
V
S
is measured at 100 V/μs.
Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
Off-state capacitance is measured at 1 MHz with a 2 V bias.
** Contact factory for release date of B-rated devices.
Electrical Parameters
Part
Number *
V
DRM
Volts
V
S
Volts
V
T
Volts
I
DRM
μAmps
I
S
mAmps
I
T
Amps
I
H
mAmps
C
O
pF
P0642S_
58
77
4
5
800
2.2
120
25
P0722S_
65
88
4
5
800
2.2
120
25
P0902S_
75
98
4
5
800
2.2
120
25
P1102S_
90
130
4
5
800
2.2
120
20
P3002S_
280
360
4
5
800
2.2
120
15
Surge Ratings
Series
I
PP
2x10 μs
Amps
I
PP
8x20 μs
Amps
I
PP
10x160 μs
Amps
I
PP
10x560 μs
Amps
I
PP
10x1000 μs
Amps
I
TSM
60 Hz
Amps
di/dt
Amps/μs
A
150
150
90
50
45
20
500
B**
250
250
150
100
80
30
500