10-24
MULTIJUNCTION TIMERS
10
32192/32195/32196 Group Hardware Manual
Rev.1.10 REJ09B0123-0110 Apr.06.07
TIN Input Processing Control Register 2 (TINCR2)
<Address: H’0080 0216>
<Upon exiting reset: H’0000>
b
Bit Name
Function
R
W
0–4
No function assigned. Fix to "0."
00
5–7
TIN11S
000: Disable input
R
W
TIN11 input processing select bit
001: Rising edge
010: Falling edge
011: Both edges
100: "L" level
101: "L" level
110: "H" level
111: "H" level
8
No function assigned. Fix to "0."
00
9–11
TIN10S
000: Disable input
R
W
TIN10 input processing select bit
001: Rising edge
010: Falling edge
011: Both edges
100: "L" level
101: "L" level
110: "H" level
111: "H" level
12
No function assigned. Fix to "0."
00
13–15
TIN9S
000: Disable input
R
W
TIN9 input processing select bit
001: Rising edge
010: Falling edge
011: Both edges
100: "L" level
101: "L" level
110: "H" level
111: "H" level
Note: This register must always be accessed in halfwords.
b0
12
34
56
78
9
10
11
12
13
14
b15
TIN11S
TIN10S
TIN9S
00
0
00
0
10.2 Common Units of Multijunction Timers