2.2.5. Command Mode
AT Command Mode provides access to AT-Settable parameters. These parameters extend flexibil-
ity in configuring modems to fit specific design criteria such as networking modems. Not all of the
parameters in the XCite Module can be adjusted using AT Commands.
AT Command Mode
To Enter AT Command Mode:
Default AT Command Mode Sequence (for transition to Command Mode):
" No characters sent for one second [refer to the BT (Guard Time Before) Command]
" Input three plus characters (+++) within one second
[refer to the CC (Command Sequence Character) Command.]
" No characters sent for one second [refer to the AT (Guard Time After) Command.]
All of the parameter values in the sequence can be modified to reflect user preferences.
To Send AT Commands:
Figure?08.燬yntax爁or爏ending燗T燙ommands?/DIV>
To read a parameter value stored in the module register, leave the parameter field blank.
The preceding example would change the modules Destination Address to "0x1F". To store the
new value to non-volatile (long term) memory, the Write (ATWR) command must subsequently be
sent before powering off the module.
System Response. When a command is sent to the module, the module will parse and execute 
the command. Upon successful execution of a command, the module returns an OK message. If
execution of a command results in an error, the module returns an ERROR message.
To Exit AT Command Mode:
For an example of programming the RF module using AT Commands and descriptions of each config-
urable parameter, refer to the "RF Module Configuration" chapter.
1.   Send the 3-character command sequence "+++" and observe guard times before and after
the command characters. [refer to Default AT Command Mode Sequence below.] The Ter-
minal tab (or other serial communications software) of the X-CTU Software can be used to
enter the sequence.
[OR]
2.   Assert (low) the CONFIG
 pin and turn the power going to the RF modem off and back on. To
achieve this result, simultaneously press the Reset and Config switches [Figure 1-02];
release the Reset Switch; then after 1 second, release the Config Switch. The RF Modem
then enters AT Command Mode at the modem's default baud rate
Send AT commands and parameters using the syntax shown below.
1.   If no valid AT Commands are received within the time specified by CT (Command Mode
Timeout) Command, the module automatically returns to Idle Mode.
  [OR]
2.   Send ATCN (Exit Command Mode) Command.
相關(guān)PDF資料
PDF描述
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
02110102-000 SNSR TILT RATIO 60DEG 500MA FLNG
1-5209285-2 FOPC BOA 12DB FC/UPC BP SM
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
XIB-U 功能描述:界面模塊 USB interface board 24XStream 9XCite RoHS:否 制造商:4D Systems 產(chǎn)品:Serial Converters 通道/端口數(shù)量: 數(shù)據(jù)速率: 接口類型:USB, UART 工作電源電壓:3.3 V, 5 V 最大工作溫度:
XIC25040 制造商:XIC 功能描述:25040 24HR '6
XILINXPWR-079 功能描述:電源管理IC開發(fā)工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 類型:Battery Management 工具用于評(píng)估:MAX17710GB 輸入電壓: 輸出電壓:1.8 V
XILINXPWR-080 功能描述:電源管理IC開發(fā)工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 類型:Battery Management 工具用于評(píng)估:MAX17710GB 輸入電壓: 輸出電壓:1.8 V
XILINXPWR-081 功能描述:電源管理IC開發(fā)工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 類型:Battery Management 工具用于評(píng)估:MAX17710GB 輸入電壓: 輸出電壓:1.8 V