-40C to +70C
10g's 10 to 55Hz, .06" DA
100g's no damage
100,000 Operations
20 Million Operations
Any
Plastic Cover, Epoxy sealed,
0.2 oz. ( 5.5 grams) approx.
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
Nominal Power:
CONTACTS
Contact Material:
Contact Resistance:
TIMING
Operate Time:
Release Time:
DIELECTRIC
Contacts to Coil:
Across open contacts:
Surge voltage resistance:
Insulation Resistance:
STRENGTH
75% of Nominal Voltage or less
10% of nominal voltage or more
110% of nominal voltage.
±
10%
200mW Approx.
Silver Alloy
100 Milliohms initial @ 6VDC, 1 Amp
10 mS Max. @ Nominal Voltage.
10 mS Max. @ Nominal Voltage.
2000 V rms
1000 V rms
5000 V rms between coil and contacts
500 VDC Exceeds 1000 Megohms min..
SPST-NO
.015 x .030
(.4 x .8) 3 Places
0.50
(12.7)
.138
(3.5)
OUTLINE DIMENSIONS
Dimensions shown are in "Inch" and ( Millimeter)
.787 Max.
(20)
.394
Max.
(10)
0.20 Dia.
(0.5) 2 Coil Terminals
CIRCUIT BOARD SPACING
Layout shown is on a 0.100 Grid
BOTTOM VIEW
ACTUAL SIZE
-
+
SPDT
+
-
.051 Dia.
(1.3)
5 Places
SERIES 276
DTL COMPATIBLE
SINGLE SIDE STABLE DESIGN
5KV SURGE RESISTANCE COIL TO CONTACT
MEETS INTERNATIONAL SPACING -4 mm COIL TO CONTACT
SPECIFICATIONS SERIES 276
TEMPERATURE
Operating::
VIBRATION
Functional:
RESISTANCE
SHOCK
Functional:
RESISTANCE
LIFE
Electrical (Rated Load):
Mechanical ( No Load):
MISCELLANEOUS
Operating Position:
Enclosure:
Weight:
WIRING DIAGRAM
BOTTOM VIEW
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
276
SERIES
MINIATURE POWER RELAY 10 AMP, P.C. MOUNTABLE
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPDT
SPDT
SPDT
SPDT
Nominal
Resis-
tance
(Ohms)
125
180
720
2880
125
180
720
2880
Nominal
Input
Voltage
5 VDC
6 VDC
12 VDC
24 VDC
5 VDC
6 VDC
12 VDC
24 VDC
Nominal
power
(mW)
200
200
200
200
200
200
200
200
COIL -
Measured at 25C
276AXXH-5D
276AXXH-6D
276AXXH-12D
276AXXH-24D
276XAXH-5D
276XAXH-6D
276XAXH-12D
276XAXH-24D
Part Numbers
Contact
Configuration
Struthers-Dunn
PAGE 44
SPST-NO
10 AMPS @ 250 VAC
10 AMPS @ 30 VDC
300 WATTS (DC)
2500 VA (AC)
10 AMPERES
125 VDC
380 VAC
1/6 HP @ 120 VAC
B300
SPDT
7 AMPS @ 250 VAC
7 AMPS @ 30 VDC
210 WATTS (DC)
1750 VA (AC)
7 AMPERES
125 VDC
380 VAC
1/10 HP @ 120 VAC
B300
NOTE: Coil polarity must be observed. Relay is polarized with a permanent magnet and will not
be damaged with reverse polarity but will not operate with reverse polarity.
PART NUMBERS SHOWN ALSO
AVAILABLE THRU STOCKING DISTRIBUTION.
CONTACT LOAD RATINGS
LOAD CONDITION
RESISTIVE LOADS:
* MAX. SWITCHING POWER:
* MAX. SWITCHING CURRENT:
* MAX. SWITCHING VOLTAGE:
MOTOR:
PILOT DUTY:
* Voltage current, and power ratings in the table above are
independent maximums and no single value is to be exceeded.
LOW LEVEL LOADS: NOT SUITABLE BELOW
20 WATTS