GENERAL SPECIFICATIONS
COIL
Pull-in voltage:
Dropout voltage:
Coil resistance:
Nominal power:
Maximum coil dissipation:
Duty:
Insulation System:
CONTACTS
Contact material:
Contact Gap:
Contact resistance:
TIMING
Operate time, (excluding bounce):
Release time, (excluding bounce):
DIELECTRIC STRENGTH
Insulation resistance:
TEMPERATURE
Operating:
Storage:
LIFE
Electrical:
Mechanical:
MISCELLANEOUS
Enclosure:
Operating Position:
Insulation material:
Terminals:
Weight:
80% of nominal voltage or less. for DC coils.
85% of nominal voltage or less for AC coils.
10% of nominal voltage or more.
±
10 % Measured at 25C
1.44 Watts for DC coils, 2VA to 3.5VA for AC coils
Capability of DC coils 2.5 Watts max.
Continuous
Class "B" coil system. (130C per UL std. 1446).
1/4" silver cadmium oxide, gold flashed.
.015 min. is standard.
50 Milliohms maximum initial resistance at rated current
20 milliseconds max.at nominal voltage.
20 milliseconds max.at nominal voltage.
1,000 Megohms min. @ 500 VDC
-30C to +50C (AC), -30C to +65C (DC)
-30C to 100C
100,000 at rated load.
5 Million Operations no load
Clear Polycarbonate dust cover
Any
Molded plastic
1/4" x .032 Q.C. Terminals suitable for solder or Q.C. connectors,
also available with Printed Circuit terminals. (.090 x .032)
3.3 oz.. (94 g approx. with cover).
389
C L A S S
PAGE 27
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
OPTIONAL
TOP FLANGE COVER
IS AVAILABLE ON
SPECIAL ORDER.
CONSULT FACTORY.
1.90Max.
(48.4)
1.40Max.
(35.5)
2.53
(64.29)
1.41
(35.8)
.500
(12.7)
SPECIFICATIONS CLASS 389 RELAYS
The 300 series was developed as a 600 Volt relay that would accept 1/4" booted
terminals. Its extra spacing permits contact gaps to 2 millimeters when required.
This increases dielectric strength across open contacts to 2500 Volts RMS.
Consult factory for details or additional information.
ALSO