PAGE 139
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT MATERIAL:
CONTACT
INSULATION
CHARACTERISTICS
DIELECTRIC
COIL DATA
RESISTANCE:
AMBIENT
OPERATIONAL:
STORAGE:
TIMING VALUES
OPERATE:
RELEASE:
TEMPERATURE
AC - VOLTAGE:
DC - VOLTAGE:
POWER
VA, (VAC):
WATTS, (VDC):
STRENGTH:
APPROVALS
DIMENSIONS
GENERAL DATA
CONTACT DATA
LIFE
MECHANICAL:
ELECTRICAL:
RELAY SERIES
1.37 X 1.00 X 2.10
214 (GFI)
SMALL OPEN STYLE
GROUND FAULT INTER-
RUPT RELAY.
MAX. OVER LOAD 120
AMPS @ 120VAC
PIERCED SOLDER LUG
TERMINALS WITH #17
AWG SILICONE WIRE
MOUNTING WITH 6-32
TAPPED HOLE & ANTI-
ROTATION TAB
DPDT (2 FORM C)
20 AMPS @ 120/240VAC
20 AMPS @ 30 VDC
120AMPS @ 120VAC
(10 CYCLES)
2000 V rms
- 45 C to + 65 C
15 MILLISECONDS
15 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
D W L
SILVER, CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
6, 12, 24, 120 VAC
6, 12, 24, 110-125 VDC
-
-
3.36 X 3.75 X 5.06
MDR
MERCURY DISPLACEMENT RELAY
(MDR)
UP TO 3 POLES, NO OR NC &
COMBINATIONS OF NO & NC
ENCAPSULATED COIL..
UP TO 100 AMPS SWITCHING
LOW CONTACT RESISTANCE
PANEL MOUNTED VERTICAL
±
15
1 to 3PST-NO or NC
35 TO 100 AMPS @
120-480VAC.
25-50 AMPS @ 600VAC
100 AMPS, 24-48 VDC
80 AMPS, 120VDC
2650 V rms
- 35 C to + 60 C
50 MILLISECONDS
100 MILLISECONDS
5 MILLION OPERATIONS
100,000 OPERATIONS
D W L
MERCURY
2 MILLIOHMS
120 & 240 VAC
24 VDC
33 VA
9 WATTS
1500 V rms
SILVER CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
12 to 240 VAC
6 to 220 VDC
-
20 WATTS
D W L
- 45 C to + 65 C (DC)
60 MILLISECONDS
30 MILLISECONDS
500,000 OPERATIONS
100,000 OPERATIONS
102, 103
HEAVY DUTY DC SOLENOID STYLE
LIGHTING CONTACTOR, MOUNTS TO
WATT HOUR METER ENCLOSURE.
DPST-NO-DM CONTACT CONFIGURA-
TION.
RATED UP TO 50 & 100 AMPS CONTINU-
OUS DUTY.
CONTACTS ENCLOSED IN MOLDED
PLASTIC COVER.
DC COILS AND AC FULL WAVE
RECTIFIED COILS.
DPST-NO-DM
50 & 100 AMPS @
120/240VAC,
30 VDC
3.0 X 6.0 X 6.0
FEATURES
PAGE NUMBER
PAGE 157
PAGES 165
GENERAL SPECIFICATIONS & APPLICATION DATA:
PAGE 158, 159
PAGE 160 THRU 164
Magnecraft
Struthers-Dunn
POWER , GFI AND MDR RELAYS