W6110DTX-1
W6210DTX-1
CONTROL
VOLTAGE
RANGE
3-32 VDC
24-120AC
48-240AC
3-32 VDC
3 VDC
3 VDC
1 VDC
1 VDC
MAX.
VOLTAGE
140 VAC
280 VAC
10 AMPS
10 AMPS
IDEC
CRYDOM
POTTER &
BRUMFIELD
MAX.
PULL-IN
VOLTAGE
MIN.
DROPOUT
VOLTAGE
TD1210
TD2410
PART
NUMBERS
CROSS REFERENCE TO:
0UTPUT
(Over Operating Temperature Range)
NOMINAL
VOLTAGE
RANGE
INPUT
(Over Operating Temperature Range)
-
-
SSRT120D10
SSRT240D10
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting
surface of suitable heat sink).
Part Numbers shown also available thru stocking distribution.
OUTPUT CHARACTERISTICS
INPUT CHARACTERISTICS
Input Impedance
Response Time
Maximum Rate of Rise of Off State Voltage 200 Volts per microsecond
Rated Load Current (Amps rms)
U/L Incandescent Lamp Ampere Ratings
U/L Motor Load Ampere Ratings
Non-Repetitive Surge Current one Cycle (Amps peak)
Maximum rms Overload current for 1 second
Max I
2
T For Fusing ( t= 8-3ms) A
2
sec
Thermal Resistance Junction To Case (T
J
, Max.= 115
0
C)
0
c/w
1500 ohms minimum
1/2 Cycle Max.
3 to 32 VDC
10.0
7.0
4.5
100
24
42
2.1
120 or 240 VAC
High Transient Capability
—Single output
features back to back SCR’s and internally
mounted RC (snubber) network for high dv/dt
applications.
Photo-Isolated, Zero Voltage Switching
—
Optically coupled for 4000 VAC isolation
between input and output and RFI suppression.
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
UL Recognized
File No. E52197
CLASS 6
DC CONTROLLED INPUT
WITH L.E.D. "ON" LAMP.
AC TRIAC OUTPUT.
6
C L A S S
DC CONTROLLED INPUT TRIAC OUTPUT SSR
MAX.
CURRENT
RATING
NEW!
L.E.D. "ON" LAMP
SEE CLASS 6 GENERAL SPECIFICATIONS
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 104