R8C/2C Group, R8C/2D Group
21. Electrical Characteristics
Rev.2.00
Dec 05, 2007
REJ09B0339-0200
Figure 21.2
Time delay until Suspend
NOTES:
1. The measurement condition is VCC = 2.2 V to 5.5 V and Topr =
20 to 85°C (N version) / 40 to 85°C (D version).
2. Necessary time until the voltage detection circuit operates when setting to 1 again after setting the VCA25 bit in the VCA2
register to 0.
NOTES:
1. The measurement condition is VCC = 2.2 V to 5.5 V and Topr =
20 to 85°C (N version) / 40 to 85°C (D version).
2. Time until the voltage monitor 1 interrupt request is generated after the voltage passes Vdet1.
3. Necessary time until the voltage detection circuit operates when setting to 1 again after setting the VCA26 bit in the VCA2
register to 0.
NOTES:
1. The measurement condition is VCC = 2.2 V to 5.5 V and Topr =
20 to 85°C (N version) / 40 to 85°C (D version).
2. Time until the voltage monitor 2 interrupt request is generated after the voltage passes Vdet2.
3. Necessary time until the voltage detection circuit operates after setting to 1 again after setting the VCA27 bit in the VCA2
register to 0.
Table 21.7
Voltage Detection 0 Circuit Electrical Characteristics
Symbol
Parameter
Condition
Standard
Unit
Min.
Typ.
Max.
Vdet0
Voltage detection level
2.2
2.3
2.4
V
Voltage detection circuit self power consumption
VCA25 = 1, VCC = 5.0 V
0.9
A
td(E-A)
Waiting time until voltage detection circuit operation
300
s
Vccmin
MCU operating voltage minimum value
2.2
V
Table 21.8
Voltage Detection 1 Circuit Electrical Characteristics
Symbol
Parameter
Condition
Standard
Unit
Min.
Typ.
Max.
Vdet1
Voltage detection level
2.70
2.85
3.00
V
Voltage monitor 1 interrupt request generation time
(2)40
s
Voltage detection circuit self power consumption
VCA26 = 1, VCC = 5.0 V
0.6
A
td(E-A)
Waiting time until voltage detection circuit operation
100
s
Table 21.9
Voltage Detection 2 Circuit Electrical Characteristics
Symbol
Parameter
Condition
Standard
Unit
Min.
Typ.
Max.
Vdet2
Voltage detection level
3.3
3.6
3.9
V
Voltage monitor 2 interrupt request generation time
(2)40
s
Voltage detection circuit self power consumption
VCA27 = 1, VCC = 5.0 V
0.6
A
td(E-A)
Waiting time until voltage detection circuit operation
100
s
FMR46
Suspend request
(maskable interrupt request)
Fixed time
td(SR-SUS)
Clock-dependent
time
Access restart