Tsi106 PowerPC Host Bridge Hardware Specifications Manual
31
80C1000_MA002_02
Ordering Information
1.9 Ordering Information
Table 15 provides the Tundra part-numbering nomenclature for the Tsi106. In addition to the core
frequency, the part numbering scheme also consists of a part modifier and application modifier. The part
modifier indicates any enhancements in the part from the original production design. The application
modifier may specify special bus frequencies or application conditions. Each part number also contains a
revision code. This refers to the die mask revision number and is specified in the part-numbering scheme
for identification purposes only.
1.9.1 Extended Temperature Device
This device differs slightly from the other Tsi106 offerings. The extended temperature has different
operating condition temperature requirements and VCD operating ranges (see
Table 16).1.9.1.1 Electrical and Thermal Characteristics
This section provides any changes to the AC and DC electrical specifications and thermal characteristics
for the Tsi106 parts described herein.
1.9.1.1.1 DC Electrical Characteristics
The following table describes the changed thermal operating conditions for the Tsi106 part numbers
described herein.
1.9.1.1.2 Clock AC Specifications
The following tables provides the revised VCO AC timing specifications for the parts described herein.
Assume Vdd = AVdd = 3.3 ± 5% V dc, OVdd = 3.3 ± 5% V dc, GND = 0 V dc, and -40
≤ T
j ≤ 105C.
Current Tundra
Part Number
Obsolete Motorola
Part Number
Operating Condition
Tsi106G-66JB
MPC106ARX66CG
0 to 70C
Tsi106G-66JBTR
MPC106ARX66CGR2
0 to 70C
Tsi106G-66KB
MPC106ARX66TG
-40 to 105C
Tsi106G-83JB
MPC106ARX83DG
0 to 70C
Tsi106G-83KB
MPC106ARX83TG
-40 to 105C
Table 15. Part Number Key
Table 16. Part Numbers Addressed by this Part Number Specification
Tundra Part Number
Motorola Part
Number
Operating Condition
Significant Differences
TJ (C)
Tsi106G-83KB
MPC106ARXTG
-40 to 105
Extended temperature; VCD operating range
Table 17. Recommended Operating Conditions
Characteristic
Symbol
Value
Unit
Junction temperature
Tj
-40 to 105
C