1. Determined according to IEC Standard 61967-1, Integrated Circuits - Measurement of Electromagnetic Emissions, 150
kHz to 1 GHz Part 1: General Conditions and Definitions, IEC Standard 61967-2, Integrated Circuits - Measurement of
Electromagnetic Emissions, 150 kHz to 1 GHz Part 2: Measurement of Radiated Emissions—TEM Cell and Wideband
TEM Cell Method, and SAE Standard J1752-3, Measurement of Radiated Emissions from Integrated Circuits—TEM/
Wideband TEM (GTEM) Cell Method.
2. VDD = 3 V, TA = 25 °C, fOSC = 12 MHz (crystal), fSYS = 96 MHz
3. Specified according to Annex D of IEC Standard 61967-2, Measurement of Radiated Emissions—TEM Cell and Wideband
TEM Cell Method, and Appendix D of SAE Standard J1752-3, Measurement of Radiated Emissions from Integrated
Circuits—TEM/Wideband TEM (GTEM) Cell Method.
5.1.7 Designing with radiated emissions in mind
To find application notes that provide guidance on designing your system to minimize
interference from radiated emissions:
2. Perform a keyword search for “EMC design.”
5.1.8 Capacitance attributes
Table 8. Capacitance attributes
Symbol
Description
Min.
Max.
Unit
CIN_A
Input capacitance: analog pins
—
7
pF
CIN_D
Input capacitance: digital pins
—
7
pF
5.2 Switching specifications
5.2.1 Device clock specifications
Symbol
Description
Min.
Max.
Unit
Notes
Normal run mode
fSYS
System and core clock
—
100
MHz
fBUS
Bus clock
—
50
MHz
FB_CLK
FlexBus clock
—
50
MHz
fFLASH
Flash clock
—
25
MHz
VLPR mode
fSYS
System and core clock
—
2
MHz
fBUS
Bus clock
—
2
MHz
Table continues on the next page...
General
K30 Sub-Family Data Sheet Data Sheet, Rev. 4, 3/2011.
18
Preliminary
Freescale Semiconductor, Inc.