Integrated T1/E1 LH/SH Transceiver for DS1/DSX-1 or PRI Applications
—
LXT361
Datasheet
37
Total
power
dissipation
T1
3
low power
Short Haul
P
D
–
310
380
mW
100% mark density
P
D
–
225
295
mW
50% mark density
Long Haul
P
D
–
245
325
mW
100% mark density
P
D
–
195
265
mW
50% mark density
T1
4
standard
power
Short Haul
P
D
–
470
560
mW
100% mark density
P
D
–
320
380
mW
50% mark density
Long Haul
P
D
–
350
420
mW
100% mark density
P
D
–
260
310
mW
50% mark density
E1
5
Short Haul/
Long Haul
P
D
–
275
330
mW
100% mark density
P
D
–
215
270
mW
50% mark density
Table 25. Digital Characteristics
Parameter
Sym
Min
Typ
Max
Unit
Test Conditions
High level input voltage (pins 1-5, 9-12, 17, 23-28)
2
V
IH
2.0
–
–
V
Low level input voltage (pins 1-5, 9-12, 17, 23-28)
2
V
IL
–
–
0.8
V
High level output voltage
1
(pins 6-8, 10, 11,23, 28)
2
V
OH
2.4
–
–
V
I
OUT
= 400
μ
A
Low level output voltage
1
(pins 6-8, 10, 11,23, 28)
2
V
OL
–
–
0.4
V
I
OUT
= 1.6 mA
Input leakage current
I
LL
–
–
±50
μ
A
1. Output drivers will output CMOS logic levels into CMOS loads.
2. Referenced pin numbers are for the PLCC package. Refer to
Figure 2 on page 8
for the corresponding QFP pins.
Table 26. Analog Characteristics
Parameter
Min
Typ
1
Max
Unit
Test Conditions
Recommended output load on TTIP/TRING
50
–
200
AMI Output Pulse Amplitudes
DSX-1, DS1
2.4
3.0
3.6
V
R
L
= 100
CEPT (ITU)
2.7
3.0
3.3
V
R
L
= 120
1. Typical figures are at 25
°
C and are for design aid only; not guaranteed and not subject to production testing.
2. Input signal to TCLK is jitter-free. The Jitter Attenuator is in the receive path or disabled.
3. Guaranteed by characterization; not subject to production testing.
4. Circuit attenuates jitter at 20 dB/decade above the corner frequency.
Table 24. Recommended Operating Conditions (Continued)
Parameter
Sym
Min
Typ
1
Max
Unit
Test Conditions
1. Typical figures are at 25
°
C and are for design aid only; not guaranteed and not subject to production testing.
2. TVCC and VCC must not differ by more than 0.3 V.
3. Power dissipation while driving 100
load coupled through 1:1.15 transformer and 0
resistor on TTIP/TRING. Includes
power dissipation on device and load. Digital levels are within 10% of the supply rails and digital outputs driving a 50 pF
capacity load.
4. Power dissipation while driving 100
load coupled through 1:2 transformer and 9.1
resistor on TTIP/TRING. Includes
power dissipation on device and load. Digital levels are within 10% of the supply rails and digital outputs driving a 50 pF
capacity load. This implementation has better return loss performance and is less sensitive to changes in impedances
variations.
5. Power dissipation while driving 120
load coupled through 1:2 transformer and 9.1
resistor on TTIP/TRING. Includes
power dissipation on device and load. Digital levels are within 10% of the supply rails and digital outputs driving a 50 pF
capacity load.