代理商: LSIFC929
4-9
Table 4.4
describes the Memory Interface signals.
Table 4.4
Memory Interface Signals
Name
BGA Pos
Type Strength Description
MD[31:0]
MD[31:24]
T21, T22,
T23, R20,
R21, R22,
R23, P21,
P22, P23,
N20, N21,
N22, N23,
M21, M22,
M23, L20,
L21, L22,
L23, K21,
K22, K23,
J20, J21,
J22, J23,
H20, H21,
H22, G21
I/O
4 mA
SSRAM Read/Write Data
.
Flash ROM Read/Write Data.
MP[3:0]
F21, F22,
E22, E23
I/O
4 mA
Memory Parity
. Byte lane parity as follows:
MP [0]: Parity for MD[7:0]
MP [1]: Parity for MD[15:8]
MP [2]: Parity for MD[23:16]
MP [3]: Parity for MD[31:24]
Memory Parity may be optionally even, odd, or none (not
used) as defined in the LSI Logic LSIFC909
Programming Guide These pins contain an internal
100
μ
A pull-up.
MA[21:0]
B21, A21,
C20, B20,
A20, D19,
C19, B19,
A19, C18,
B18, A18,
C17, A17,
D16, C16,
B16, A16,
D15, C15,
B15, A15
O
4 mA
SSRAM/Flash ROM Address
.
MOE[1:0]/
C22, B22
O
8 mA
Memory Output Enable
. When asserted LOW, the
selected SRAM or Flash (MOE[1]/) device may drive
data. This signal is typically an asynchronous input to
SRAM and/or Flash devices. The two output enables
allow for interleaving configurations.
相關(guān)PDF資料
PDF描述
LSIFC929X LSIFC929X dual channel fibre solutions
LSIU160 LSIU160 Ultra160 SCSI host adapter
LSIU40HVD LSIU40HVD PCI to Dual Channel SCSI host adapter user's guide v2.2 8/02
LSIU40SE LSIU40SE Dual Channel PCI to Ultra SCSI host adapter user's guide v2.2 8/02
LSIU80LVD LSIU80LVD Ultra2 LVD SCSI host adapter
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LSIFC929-329BGA 制造商:LSI Corporation 功能描述:Fiber Controller 456-Pin BGA
LSIFC929X 制造商:LSI Corporation 功能描述:- Bulk
LSIFC929XL 制造商:LSI Corporation 功能描述:2GB PCI-X TO DUAL CHANNEL - Bulk
LSIFC949X 制造商:LSI Corporation 功能描述:PCI-X TO DUAL CHANNEL - Bulk
LSIFC949X A0 制造商:LSI 功能描述: 制造商:LSI Corporation 功能描述: