AMIS-30623 LIN Microstepping Motordriver
Data Sheet
15.2.7. Autarkic functionality in under-voltage condition
Battery voltage management
The AMIS-30623 monitors the battery voltage by means of one threshold and one shutdown level, as illustrated in the state diagram
below. The only condition to reset flags <UV2> and <StepLoss> is to recover a battery voltage higher than UV1 and to receive a
or a GetFullStatus command.
Figure 17: State Diagram Battery Voltage Management
Normal voltage
- <UV2 > = ‘0’
- <StepLoss > = ‘0’
Vbb > UV1 &
LIN frame:
GetStatus
or
GetFullStatus
Vbb < UV2 &
motion ongoin g
Vbb < UV2
(no motion)
Stop mode 1
- <UV2 > = ‘ 1
- <StepLoss > = ‘0’
- Motor shutdown
(motion disabled)
Stop mode 2
- <UV2 > = ‘ 1
- <StepLoss > = ‘ 1
- HardStop
- Motor shutdown
(motion disabled)
Autarkic function
In Stop mode 1 the motor is put in shutdown state. The <UV2> flag is set. In case Vbb > UV1 AMIS-30623 accepts updates of the
target position by means of the reception of SetPosition, SetPositionShort, SetPosParam and GotoSecurePosition
commands, even if the <UV2> flag is NOT prior cleared.
In Stop mode 2 the motor is stopped immediately and put in shutdown state. The <UV2> and <Steploss> flags are set. In case Vbb
> UV1 AMIS-30623 autonomously resumes the motion to the original target position using the stored motor parameters (minimum and
maximum velocity, acceleration, step-mode, run- and hold current) in case no RAM reset occurred.
The flags are only cleared after receiving a GetStatus or GetFullStatus command.
Updates of the target position by means of the reception of SetPosition, SetPositionShort, SetPosParam and
commands is accepted, even if the <UV2> and <Steploss> flags are NOT prior cleared.
Important notes:
1.
In the case of Stop mode 2 care needs to be taken because the accumulated steploss can cause a significant deviation
between physical and stored actual position.
2.
The SetDualPosition command will only be executed after clearing the <UV2> and <Steploss> flags.
3.
RAM reset occurs when Vdd < VddReset (digital Power On Reset level)
4.
The Autarkic function remains active as long as Vdd > VddReset
Logical implementation Autarkic function
The logic uses the <UV2>, <CPFail> and <Steploss> signal NOT the state.
The state is set one clock after the signal and would therefore slow down the reaction time. Also the state can only be cleared after a
or GetFullStatus command which prevents the autonomous function.
Only <UV2> and <CPFail> are applicable for finishing the motion to the original target position:
<UV2> needs to be cleared to leave the Shutdown State
<CPFail> needs to be cleared to avoid a new HardStop after entering the GotoPos state
25
AMI Semiconductor
– June 2006, Rev 3.0
www.amis.com
相關(guān)PDF資料
PDF描述
AMMC-2008 0 MHz - 50000 MHz RF/MICROWAVE SGL POLE DOUBLE THROW SWITCH, 2.3 dB INSERTION LOSS
AMR2803R3S/EM 1-OUTPUT 25 W DC-DC REG PWR SUPPLY MODULE
AMR2803R3S/EMPBF 1-OUTPUT 25 W DC-DC REG PWR SUPPLY MODULE
AMR2815S/EM 1-OUTPUT 30 W DC-DC REG PWR SUPPLY MODULE
AN1458S DUAL OP-AMP, 4000 uV OFFSET-MAX, PDSO8
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AMIS-30623AANA 制造商:AMI 制造商全稱:AMI 功能描述:LIN Microstepping Motordriver
AMIS-30623BAGA 制造商:AMI 制造商全稱:AMI 功能描述:LIN Microstepping Motordriver
AMIS-30623BANA 制造商:AMI 制造商全稱:AMI 功能描述:LIN Microstepping Motordriver
AMIS30623C6238G 功能描述:馬達(dá)/運(yùn)動/點(diǎn)火控制器和驅(qū)動器 LIN STEPPER DRIVER STALL RoHS:否 制造商:STMicroelectronics 產(chǎn)品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube
AMIS30623C6238RG 功能描述:馬達(dá)/運(yùn)動/點(diǎn)火控制器和驅(qū)動器 LIN STEPPER DRIVER STALL RoHS:否 制造商:STMicroelectronics 產(chǎn)品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube