NB6L56
http://onsemi.com
5
Table 5. DC CHARACTERISTICS VCC = 2.5 ± 5% (2.375 V to 2.625 V); VCC = 3.3 ± 10% (3.0 V to 3.6 V) (Note 5) Symbol
Characteristic
Min
Typ
Max
Unit
ICC
Power Supply Current (Inputs and Outputs Open)
65
85
mA
LVPECL OUTPUTS
VOH
Output HIGH Voltage
VCC – 1.145
VCC 0.895
mV
VOL
Output LOW Voltage
VCC – 2.000
VCC 1.695
mV
VOUT
Output Swing (Single Ended)
Output Swing (Differential)
400
800
1600
mV
DIFFERENTIAL INPUT DRIVEN SINGLEENDED (Note
6) (Figures
5 and
6) Vth
Input Threshold Reference Voltage Range
1125
VCC 75
mV
VIH
Singleended Input HIGH Voltage
Vth + 75
VCC
mV
VIL
Singleended Input LOW Voltage
GND
Vth 75
mV
VISE
Singleended Input Voltage (VIH VIL ) (Note 6) 150
3015
mV
DIFFERENTIAL INPUTS DRIVEN DIFFERENTIALLY (Note
7) (Figures
7 and
8) VIHD
Differential Input HIGH Voltage
1200
VCC
mV
VILD
Differential Input LOW Voltage
GND
VIHD 100
mV
VID
Differential Input Voltage (VIHD VILD)
100
1890
mV
VCMR
Input Common Mode Range (Differential Configuration) (Figure
9)1150
VCC 50
mV
IIH
Input HIGH Current (VTnx Open)
150
mA
IIL
Input LOW Current (VTnx Open)
150
mA
LVTTL / LVCMOS INPUTS (SELA/SELB)
VIH
Input HIGH Voltage
2.0
V
VIL
Input LOW Voltage
0.8
V
IIL
Input LOW Current (VIN = 0.5 V)
300
mA
IIH
Input HIGH Current (VCC)
75
mA
TERMINATION RESISTORS
RTIN
Internal Input Termination Resistor INxn/INxn to VTxn
45
50
55
W
REFERENCE VOLTAGE
VREFAC
Output Reference Voltage
VCC 1.35
VCC 1.2
VCC 1.1
V
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Outputs evaluated with 50 W resistors to VTT = VCC 2.0 V for proper operation (See Figure 16). 6. VTH is applied to the complementary input when operating in singleended mode. VIH, VIL and VTH parameters must be complied with
simultaneously.
7. VIHD, VILD and VCMR parameters must be complied with simultaneously. VCMR max varies 1:1 with VCC.