Clock-Synchronous Serial I/O
M30240 Group
Rev.1.00 Sep 24, 2003 Page 177 of 360
2.4 Clock-Synchronous Serial I/O
2.4.1 Overview
Clock-synchronous serial I/O carries out 8-bit data communications in synchronization with the clock.
The following is an overview of the clock-synchronous serial I/O.
2.4.1.1 Transmission/reception format
8-bit data
2.4.1.2 Transfer rate
If the internal clock is selected as the transfer clock, the divide-by-2 frequency, resulting from the bit rate
generator division, becomes the transfer rate. The bit rate generator count source can be selected from
the following: f1, f8, and f32. Clocks f1, f8, and f32 are derived by dividing the CPU’s main clock by 1,
8, and 32 respectively.
Furthermore, if an external clock is selected as the transfer clock, the clock frequency input to the CLK
pin becomes the transfer rate.
2.4.1.3 Error detection
Only an overrun error can be detected. An overrun error is an error that occurs when the next data is
made ready before the reception buffer register is read.
2.4.1.4 How to deal with an error
When receiving data, read an error flag and reception data simultaneously to determine which error has
occurred. If the data read is erroneous, initialize the error flag and the UARTi receive buffer register, then
receive the data again.
To initialize the UARTi receive buffer register
1. Set the receive enable bit to “0” (disable reception).
2. Set the serial I/O mode select bit to “0002” (invalid serial I/O).
3. Set the serial I/O mode select bit.
4. Set the receive enable bit to “1” again (enable reception).
To transmit data again due to an error on the reception side, set the UARTi transmit buffer register again,
then transmit the data again.
To set the UARTi transmit buffer register again
1. Set the serial I/O mode select bits to “0002” (invalid serial I/O).
2. Set the serial I/O mode select bits again.
3. Set the transmit enable bit to “1” (enable transmission), then set transmission data in the UARTi
2.4.1.5 Function selection
For clock-synchronous serial I/O, the following functions can be selected:
(a) CTS/RTS function
In the CTS function, an external IC can start transmission/reception by inputting an “H” level to the
CTS pin. The CTS pin input level is detected when transmission/reception starts. Therefore, if the level
is set to “L” during transmission/reception, it will stop from the next data.
The RTS function informs an external IC that RTS is reception-ready and has changed to “L”. RTS
goes to “H” at the falling edge of the transfer clock.