ADT7476
Rev. B | Page 16 of 72
Write Byte
In this operation, the master device sends a command byte
and one data byte to the slave device, as follows:
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by
the write bit (active low).
3.
The addressed slave device asserts ACK on SDA.
4.
The master sends a command code.
5.
The slave asserts ACK on SDA.
6.
The master sends a data byte.
7.
The slave asserts ACK on SDA.
8.
The master asserts a stop condition on SDA,
and the transaction ends.
This operation is illustrated in Figure 22.
05382-023
SLAVE
ADDRESS W A
DATA
SA
REGISTER
ADDRESS
23
15
4
A P
6
7 8
Figure 22. Single-Byte Write to a Register
READ OPERATIONS
The ADT7476 uses the following SMBus read protocols.
Receive Byte
This operation is useful when repeatedly reading a single
register. The register address is set up previously. In this
operation, the master device receives a single byte from a slave
device, as follows:
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
read bit (high).
3.
The addressed slave device asserts ACK on SDA.
4.
The master receives a data byte.
5.
The master asserts NO ACK on SDA.
6.
The master asserts a stop condition on SDA, and the
transaction ends.
In the ADT7476, the receive byte protocol is used to read a
single byte of data from a register whose address has been set by
a send byte or write byte operation. This operation is illustrated
05
38
2-
02
4
SLAVE
ADDRESS
DATA
A
R
SA
24
3
15
P
6
Figure 23. Single-Byte Read from a Register
Alert Response Address
Alert response address (ARA) is a feature of SMBus devices that
allows an interrupting device to identify itself to the host when
multiple devices exist on the same bus.
The SMBALERT output can be used as either an interrupt out-
put or an SMBALERT. One or more outputs can be connected
to a common SMBALERT line connected to the master. If a device
SMBALERT line goes low, the following procedure occurs:
1.
SMBALERT is pulled low.
2.
The master initiates a read operation and sends the alert
response address (ARA = 0001 100). This is a general call
address that must not be used as a specific device address.
3.
The device whose SMBALERT output is low responds to
the alert response address, and the master reads its device
address. The address of this device is now known and can
be interrogated in the usual way.
4.
If more than one device’s SMBALERT output is low, the
one with the lowest device address has priority in accor-
dance with normal SMBus arbitration.
5.
Once the ADT7476 has responded to the alert response
address, the master must read the status registers, and the
SMBALERT is cleared only if the error condition is gone.
SMBus TIMEOUT
The ADT7476 includes an SMBus timeout feature. If there is no
SMBus activity for 35 ms, the ADT7476 assumes that the bus is
locked and releases the bus. This prevents the device from
locking or holding the SMBus expecting data. Some SMBus
controllers cannot handle the SMBus timeout feature, so it can
be disabled.
Configuration Register 1 (0x40)
Bit 6 TODIS = 0, SMBus timeout disabled (default)
Bit 6 TODIS = 1, SMBus timeout enabled
VIRUS PROTECTION
To prevent rogue programs or viruses from accessing critical
ADT7476 register settings, the lock bit can be set. Setting Bit 1
of Configuration Register 1 (0x40) sets the lock bit and locks
critical registers. In this mode, certain registers can no longer be
written to until the ADT7476 is powered down and powered up
again. For more information on which registers are locked, see
the Register Tables section.
相關(guān)PDF資料
PDF描述
ADT7482ARMZ-RL DIGITAL TEMP SENSOR-SERIAL, 11BIT(s), 2.5Cel, SQUARE, SURFACE MOUNT
ADT7482ARMZ-U2 DIGITAL TEMP SENSOR-SERIAL, 11BIT(s), 2.5Cel, SQUARE, SURFACE MOUNT
ADT7485ARMZ-REEL DIGITAL TEMP SENSOR-SERIAL, 16BIT(s), 1Cel, SQUARE, SURFACE MOUNT
ADT7485ARMZ DIGITAL TEMP SENSOR-SERIAL, 16BIT(s), 1Cel, SQUARE, SURFACE MOUNT
ADT7485ARMZ-REEL7 DIGITAL TEMP SENSOR-SERIAL, 16BIT(s), 1Cel, SQUARE, SURFACE MOUNT
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADT7476EBZEVB 功能描述:BOARD EVALUATION FOR ADT7476 RoHS:是 類別:編程器,開發(fā)系統(tǒng) >> 過時/停產(chǎn)零件編號 系列:dBCool® 標(biāo)準(zhǔn)包裝:1 系列:- 傳感器類型:CMOS 成像,彩色(RGB) 傳感范圍:WVGA 接口:I²C 靈敏度:60 fps 電源電壓:5.7 V ~ 6.3 V 嵌入式:否 已供物品:成像器板 已用 IC / 零件:KAC-00401 相關(guān)產(chǎn)品:4H2099-ND - SENSOR IMAGE WVGA COLOR 48-PQFP4H2094-ND - SENSOR IMAGE WVGA MONO 48-PQFP
ADT7481 制造商:AD 制造商全稱:Analog Devices 功能描述:Dual Channel Temperature Sensor and Over Temperature Alarm
ADT7481ARMZ 功能描述:板上安裝溫度傳感器 2 CH TEMP SNSR/ALARM 2 WIRE SMBUS INTRFCE RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
ADT7481ARMZ-001 功能描述:板上安裝溫度傳感器 2 CH TEMP SNSR/ALARM 2 WIRE SMBUS INTRFCE RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
ADT7481ARMZ-1 功能描述:IC SENSOR TEMP 2CH ALARM 10MSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風(fēng)扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6