Removing Temperature Errors
As CPUs run faster and faster, it gets more difficult to
avoid high frequency clocks when routing the D+ and D
traces around a system board. Even when the recommended
layout guidelines are followed, temperature errors attributed
to noise coupled onto the D+ and D lines remain. High
frequency noise generally gives temperature measurements
that are consistently too high. The ADM1034 has Local,
Remote 1, and Remote 2 temperature offset registers at
0x16, 0x17, and 0x18; one for each channel. By completing
a one-time calibration, the user can determine the offset
caused by the system board noise and remove it using the
offset registers. The registers automatically add a twos
compliment word to the remote temperature measurements,
ensuring correct readings in the value registers.
Table 13. OFFSET REGISTERS
Registration
Description
Default
0x16
Local Offset
0x00
0x17
Remote 1 Offset
0x00
0x18
Remote 2 Offset
0x00
Table 14. OFFSET REGISTER VALUES
Code
Offset Value
0 0000 000
0癈 (Default Value)
0 0000 001
0.125癈
0 0000 111
0.875癈
0 0001 111
1.875癈
0 0111 111
7.875癈
0 1111 111
15.875癈
1 0000 000
16癈
1 1111 000
0.875癈
Layout Considerations
Digital boards can be electrically noisy environments. Try
to protect the analog inputs from noise, particularly when
measuring the very small voltages from a remote diode
sensor. Take the following precautions:
?SPAN class="pst ADM1034ARQZ-REEL_2295499_3"> Place the ADM1034 as close as possible to the remote
sensing diode. A distance of 4 inches to 8 inches is
adequate, provided that the worst noise sources such as
clock generators, data/address buses, and CRTs are
avoided.
?SPAN class="pst ADM1034ARQZ-REEL_2295499_3"> Route the D+ and D tracks close together, in parallel,
with grounded guard tracks on each side. Provide a
ground plane under the tracks if possible.
?SPAN class="pst ADM1034ARQZ-REEL_2295499_3"> Use wide tracks to minimize inductance and reduce
noise pickup. At least 5 mil track width and spacing are
recommended.
Figure 28. Arrangement of Signal Tracks
5 MIL
5 MIL
5 MIL
5 MIL
5 MIL
5 MIL
5 MIL
GND
D
D+
GND
?SPAN class="pst ADM1034ARQZ-REEL_2295499_3"> Try to minimize the number of copper/solder joints,
because they can cause thermocouple effects. Where
copper/solder joints are used, make sure that they are in
both the D+ and D paths and at the same temperature.
Thermocouple effects are not a major problem because
1癈 corresponds to approximately 200 mV, and
thermocouple voltages are approximately 3 mV/癈 of
temperature difference. Unless there are two
thermocouples with a big temperature differential
between them, the voltages should be much less than
200 mV.
?SPAN class="pst ADM1034ARQZ-REEL_2295499_3"> Place a 0.1 mF bypass capacitor close to the ADM1034.
?SPAN class="pst ADM1034ARQZ-REEL_2295499_3"> If the distance to the remote sensor is more than
8 inches, twisted pair cable is recommended. This
works up to about 6 feet to 12 feet.
?SPAN class="pst ADM1034ARQZ-REEL_2295499_3"> For very long distances (up to 100 feet), use shielded
twisted pair such as Belden #8451 microphone cable.
Connect the twisted pair to D+ and D and the shield to
GND, close to the ADM1034. Leave the remote end of
the shield unconnected to avoid ground loops.
Because the measurement technique uses switched
current sources, excessive cable and/or filter capacitance
can affect the measurement. When using long cables, the
filter capacitor C1 may be reduced or removed. In any case,
the total shunt capacitance should never exceed 1000 pF.
Noise Filtering
For temperature sensors operating in noisy environments,
common practice is to place a capacitor across the D+ and
D pins to help combat the effects of noise. However, large
capacitances affect the accuracy of the temperature
measurement, leading to a recommended maximum
capacitor value of 1000 pF. While this capacitor reduces the
noise, it does not eliminate it, making it difficult to use the
sensor in a very noisy environment.
The ADM1034 has a major advantage over other devices
when it comes to eliminating the effects of noise on the
external sensor. The series resistance cancellation feature
allows a filter to be constructed between the external
相關(guān)PDF資料
PDF描述
ADN8810ACPZ-REEL7 IC CURRENT SOURCE(12BIT) 24LFCSP
ADP2140ACPZ3328R7 IC REG DL BCK/LINEAR 10LFCSP
ADP5022ACBZ-6-R7 IC REG TRPL BCK/LINEAR 16WLCSP
ADP5041ACPZ-1-R7 IC REG TRPL BCK/LINEAR 20-LFCSP
ADP5042ACPZ-2-R7 IC REG TRPL BCK/LINEAR 20LFCSP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADM1034ARQZ-REEL7 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風(fēng)扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1040 制造商:AD 制造商全稱:Analog Devices 功能描述:Power Supply Monitor ASIC
ADM1041 制造商:AD 制造商全稱:Analog Devices 功能描述:Secondary-Side Controller with Current Share and Housekeeping
ADM1041A 制造商:AD 制造商全稱:Analog Devices 功能描述:Secondary-Side Controller with Current Share and Housekeeping
ADM1041AARQZ 功能描述:IC SECONDARY SIDE CTRLR 24QSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 電源控制器,監(jiān)視器 系列:- 產(chǎn)品培訓(xùn)模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標(biāo)準(zhǔn)包裝:2,500 系列:- 應(yīng)用:多相控制器 輸入電壓:- 電源電壓:9 V ~ 14 V 電流 - 電源:- 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:40-WFQFN 裸露焊盤 供應(yīng)商設(shè)備封裝:40-TQFN-EP(5x5) 包裝:帶卷 (TR)