參數(shù)資料
型號(hào): ADM1034ARQZ-REEL
廠商: ON Semiconductor
文件頁數(shù): 13/38頁
文件大?。?/td> 427K
描述: IC THERM/FAN SPEED CTRLR 16-QSOP
產(chǎn)品變化通告: MFG CHG Notification ADI to ON Semi
標(biāo)準(zhǔn)包裝: 2,500
功能: 風(fēng)扇控制,溫度監(jiān)控器
傳感器類型: 內(nèi)部和外部
感應(yīng)溫度: -40°C ~ 125°C,外部傳感器
精確度: ±1°C
拓?fù)洌?/td> ADC,比較器,多路復(fù)用器,寄存器庫
輸出類型: SMBus?
輸出警報(bào):
輸出風(fēng)扇:
電源電壓: 3 V ~ 5.5 V
工作溫度: -40°C ~ 125°C
安裝類型: 表面貼裝
封裝/外殼: 16-SSOP(0.154",3.90mm 寬)
供應(yīng)商設(shè)備封裝: 16-QSOP
包裝: 帶卷 (TR)
ADM1034
http://onsemi.com
13
Figure 22. Block Write to RAM
SLAVE
ADDRESS
S
BYTE
COUNT
DATA 2
DATA 1
REGISTER
ADDRESS
W
A
A
P
A
A
A
DATA N
A
Read Operations
Receive Byte
This is useful when repeatedly reading a single register.
The register address must be set up prior to this, with the
MSB at 0 to read a single byte. In this operation, the master
device receives a single byte from a slave device as follows:
1. The master device asserts a start condition on
SDA.
2. The master sends the 7-bit slave address followed
by the read bit (high).
3. The addressed slave device asserts ACK on SDA.
4. The master receives a data byte.
5. The master sends NO ACK on SDA.
6. The master asserts a stop condition on SDA, and
the transaction ends.
In the ADM1034, the receive byte protocol is used to read
a single byte from a register whose address has previously
been set by a send byte or write byte operation.
Figure 23. Receive Byte
SLAVE
ADDRESS
S
DATA
R
A
A
P
Block Read
In this operation, the master reads a block of data from a
slave device. The number of bytes to be read must be set in
advance. To do this, use a write byte operation to the
#Bytes/Block Read Register at Address 0x00. The register
address determines whether a block-read or a read-byte
operation is to be completed (set MSB to 1 to specify a
block-read operation). A maximum of 32 bytes can be read.
1. The master asserts a start condition on SDA.
2. The master sends the 7-bit slave address followed
by the write bit (low).
3. The addressed slave device asserts ACK on SDA.
4. The master sends the register address (MSB = 1).
5. The slave asserts ACK on SDA.
6. The master asserts a repeated start on SDA.
7. The master sends the 7-bit slave address followed
by the read bit (high).
8. The slave asserts ACK on SDA.
9. The slave sends the byte count.
10. The master asserts ACK on SDA.
11. The slave sends N data bytes.
12. The master asserts ACK on SDA after each data
byte.
13. The master does not acknowledge after the Nth
data byte.
14. The master asserts a stop condition on SDA to end
the transaction.
Figure 24. Block Read from RAM
SLAVE
ADDRESS
S
BYTE
COUNT
DATA 1
REGISTER
ADDRESS
W
A
P
A
A
A    DATA N
SLAVE
ADDRESS
S
R
A
A
SMBus Timeout
The ADM1034 has a programmable SMBus timeout
feature. When this is enabled, the SMBus typically times out
after 25 ms of no activity. The timeout is disabled by default.
It prevents hangups by releasing the bus after a period of
inactivity.
To enable the SDA timeout, set the SDA timeout bit
(Bit 5) of Configuration Register 1 (Address 0x01) to 1.
To enable the SCL timeout, set the SCL timeout bit (Bit 4)
of Configuration Register 1 (Address 0x01) to 1.
Packet Error Checking (PEC)
The ADM1034 also supports packet error checking
(PEC). This optional feature is triggered by the extra clock
for the PEC byte. The PEC byte is calculated using CRC8.
The frame check sequence (FCS) conforms to CRC8 by the
following:
(eq. 1)
C(x) + x
8
) x
2
) x ) 1
For more information, consult www.SMBus.org
.
Alert Response Address (ARA)
Figure 25. ALERT Response Address
ALERT RESPONSE
ADDRESS
S
DEVICE
ADDRESS
R
A
A
P
When multiple devices exist on the same bus, the ARA
feature allows an interrupting device to identify itself to the
host.
The ALERT
 output can be used as an interrupt output or
as an SMBusALERT
. One or more ALERT
 outputs can be
connected to a common SMBusALERT
 line, connected to
the master.
If a devices ALERT
 line goes low, the following occurs:
1. SMBusALERT
 is pulled low.
2. The master initiates a receive byte operation and
sends the alert response address (ARA 0001 100).
This is a general call address that must not be used
as a specific address.
3. The device with the low ALERT
 output responds
to the ARA, and the master reads its device
address. Once the address is known, it can be
interrogated in the usual way.
4. If low ALERT
 output is detected in more than one
device, the one with the lowest device address has
priority, in accordance with normal SMBus
arbitration.
5. Once the ADM1034 has responded to the ARA, it
resets its ALERT
 output. However, if the error
persists, the ALERT
 is re-asserted on the next
monitoring cycle.
相關(guān)PDF資料
PDF描述
ADN8810ACPZ-REEL7 IC CURRENT SOURCE(12BIT) 24LFCSP
ADP2140ACPZ3328R7 IC REG DL BCK/LINEAR 10LFCSP
ADP5022ACBZ-6-R7 IC REG TRPL BCK/LINEAR 16WLCSP
ADP5041ACPZ-1-R7 IC REG TRPL BCK/LINEAR 20-LFCSP
ADP5042ACPZ-2-R7 IC REG TRPL BCK/LINEAR 20LFCSP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADM1034ARQZ-REEL7 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報(bào):無 輸出風(fēng)扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1040 制造商:AD 制造商全稱:Analog Devices 功能描述:Power Supply Monitor ASIC
ADM1041 制造商:AD 制造商全稱:Analog Devices 功能描述:Secondary-Side Controller with Current Share and Housekeeping
ADM1041A 制造商:AD 制造商全稱:Analog Devices 功能描述:Secondary-Side Controller with Current Share and Housekeeping
ADM1041AARQZ 功能描述:IC SECONDARY SIDE CTRLR 24QSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 電源控制器,監(jiān)視器 系列:- 產(chǎn)品培訓(xùn)模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標(biāo)準(zhǔn)包裝:2,500 系列:- 應(yīng)用:多相控制器 輸入電壓:- 電源電壓:9 V ~ 14 V 電流 - 電源:- 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:40-WFQFN 裸露焊盤 供應(yīng)商設(shè)備封裝:40-TQFN-EP(5x5) 包裝:帶卷 (TR)